Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

volatiles[x]

Enter more terms to filter the results further.

Searching in: GC, Split
marketnum

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven

GC_EV1475

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-Scan
GC_EV1475

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven

GC_EV1476

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-Scan
GC_EV1476

Semivolatiles on Rxi-5ms (Split Injection)

GC_EV1418

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_EV1418

9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D

GC_EV1328

Column: Rxi-5ms, 10 m, 0.18 mm ID, 0.18 µm, using Rxi-5ms 2 m, 0.18 mm ID,, with 0.4 mm OD matched press-fit, BGB (cat.# 2525LD)
Injector: Split
Detector: MS-Scan
GC_EV1328

Semivolatiles With Appendix IX on Rxi-5ms by 8270D

GC_EV1304

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_EV1304

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)

GC_EV1248

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Split
Detector: MS-Scan
GC_EV1248

Alcohols Rtx-Volatiles

GC_CH00293

Column: Rtx-Volatiles, 60 m, 0.32 mm ID, 1.50 µm (cat.# 10904)
Injector: Split
Detector: FID
GC_CH00293

Separation of Ethanol and Aromatics from Paraffins in Gasoline with GCxGC on Rtx-DHA-150 and Stabilwax

GC_PC1227

Column: Rtx-DHA-150 150 m, 0.25 mm ID, 1.00 µm (cat.# 10149)Stabilwax 1 m, 0.18 mm ID, 0.18 µm (cat.# 15118)
Injector: Split
Detector: FID
GC_PC1227

p- and m-Xylenes in Gasoline by GCxGC on Rtx-DHA-150 and Stabilwax

GC_PC1226

Column: Rtx-DHA-150 150 m, 0.25 mm ID, 1.00 µm (cat.# 10149)Stabilwax 1 m, 0.18 mm ID, 0.18 µm (cat.# 15118)
Injector: Split
Detector: FID
GC_PC1226

Volatile Solvents on Rtx-Wax

GC_CH00347

Column: Rtx-Wax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 12455)
Injector: Split
Detector: FID
GC_CH00347

Solvents on Rtx-Volatiles

GC_CH00352

Column: Rtx-Volatiles, 60 m, 0.53 mm ID, 2.00 µm (cat.# 10905)
Injector: Split
Detector: TCD
GC_CH00352

Flavor Volatiles on Rtx-1

GC_FF00536

Column: Rtx-1, 60 m, 0.53 mm ID, 0.50 µm (cat.# 10143)
Injector: Split
Detector: FID
GC_FF00536

Flavor Volatiles on Stabilwax

GC_FF00537

Column: Stabilwax, 60 m, 0.53 mm ID, 0.50 µm (cat.# 10643)
Injector: Split
Detector: FID
GC_FF00537

Freon 12 and Ethylene Oxide on Rtx-1

GC_CH00324

Column: Rtx-1, 30 m, 0.53 mm ID, 5.00 µm (cat.# 10179)
Injector: Split
Detector: FID
GC_CH00324

Short Chain Amines in Water on Rtx-Volatile Amine

GC_GN1154

Column: Rtx-Volatile Amine, 60 m, 0.32 mm ID (cat.# 18078)
Injector: Split
Detector: FID
GC_GN1154

Impurity Analysis of 1,1,1,2-Tetrafluoroethane (CFC-134a) on Rt-Alumina BOND/CFC

GC_GN1155

Column: Rt-Alumina BOND/CFC, 30 m, 0.53 mm ID (cat.# 19763)
Injector: Split
Detector: FID
GC_GN1155

Microbial VOCs on Rxi-1ms

GC_AR01030

Column: Rxi-1ms, 60 m, 0.25 mm ID, 1.00 µm (cat.# 13356)
Injector: Split
Detector: Agilent 5973 GC/MS
GC_AR01030

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us