Cocaine and Metabolites (TMS Derivatives) on Rxi-5Sil MS (100 ng/mL)
This chromatogram may contain analytes that are synonyms of your search terms.

Cocaine and Metabolites (TMS Derivatives) on Rxi-5Sil MS (100 ng/mL)

Peaks m/z 1m/z 2m/z 3
1.Ecgonine methyl ester8296256
2.Ecgonine8296356
3.Cocaine82182303
4.Cocaethylene82196317
5.Benzoylecgonine8296346
6.Cannabinol*409----
image
GC_CF1149
ColumnRxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Sample
Diluent:Butyl chloride
Conc.:100 ng/mL
Injection
Inj. Vol.:1 µL splitless (hold 1 min)
Liner:Single taper w/wool (cat.# 22286-200.1)
Inj. Temp.:250 °C
Purge Flow:20 mL/min
Oven
Oven Temp.:100 °C to 200 °C at 30 °C/min to 300 °C at 15 °C/min
Carrier GasHe, constant linear velocity
Linear Velocity:40 cm/sec, 12.5 psi, 86.2 kPa @ 100 °C
DetectorMS
Mode:SIM
Transfer Line Temp.:310 °C
Source Temp.:250 °C
Solvent Delay Time:4 min
Tune Type:PFTBA
Ionization Mode:EI
InstrumentShimadzu 2010 GC & QP2010+ MS
NotesSamples were prepared as follows:
Standards brought to dryness under nitrogen, then 50 µL BSTFA + 1% TMCS (cat.# 35606) were added. 50 µL pyridine was then added, and samples were incubated at 70 °C for 30 min. After incubation, samples were diluted with butyl chloride.

* Cannabinol was used as a derivatization check.
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

Cocaine

,

Rxi-5SilMS

,

,

Rxi

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us