share:
delim
delim
Volatile Organics by EPA 8021 on Rtx-VRX

Volatile Organics by EPA 8021 on Rtx-VRX

Peaks
1.Dichlorodifluoromethane
2.Chloromethane
3.Vinyl chloride
4.Bromomethane
5.Chloroethane
6.Trichlorofluoromethane
7.1,1-Dichloroethene
8.Methylene chloride
9.Freon® 113
10.trans-1,2-Dichloroethene
11.Methyl tert-butyl ether
12.1,1-Dichloroethane
13.cis-1,2-Dichloroethene
14.Bromochloromethane
15.Chloroform
16.2,2-Dichloropropane
17.1,2-Dichloroethane
18.1,1,1-Trichloroethane
19.1,1-Dichloropropene
20.Carbon tetrachloride
21.Benzene
22.Fluorobenzene (SS)
23.Dibromomethane
24.1,2-Dichloropropane
25.Trichloroethene
26.Bromodichloromethane
27.2-Chloroethyl vinyl ether
28.cis-1,3-Dichloropropene
29.trans-1,3-Dichloropropene
30.1,1,2-Trichloroethane
31.Toluene
32.1,3-Dichloropropane
33.Dibromochloromethane
Peaks
34.1,2-Dibromoethane
35.Tetrachloroethene
36.1,1,1,2-Tetrachloroethane
37.Chlorobenzene
38.Ethylbenzene
39.m-Xylene
40.p-Xylene
41.Bromoform
42.Styrene
43.1,4-Dichlorobutane (SS)
44.1,1,2,2-Tetrachloroethane
45.o-Xylene
46.1,2,3-Trichloropropane
47.Isopropylbenzene
48.Bromobenzene
49.n-Propylbenzene
50.2-Chlorotoluene
51.4-Chlorotoluene
52.1,3,5-Trimethylbenzene
53.tert-Butylbenzene
54.1,2,4-Trimethylbenzene
55.sec-Butylbenzene
56.1,3-Dichlorobenzene
57.1,4-Dichlorobenzene
58.p-Isopropyltoluene
59.1,2-Dichlorobenzene
60.n-Butylbenzene
61.1,2-Dibromo-3-Chloropropane
62.4-Bromochlorobenzene (SS)
63.1,2,4-Trichlorobenzene
64.Naphthalene
65.Hexachlorobutadiene
66.1,2,3-Trichlorobenzene
image
GC_EV00001
ColumnRtx-VRX, 75 m, 0.45 mm ID, 2.55 µm (cat.# 19309)
Sample502.2 CAL2000 MegaMix Mixture (cat.# 30431)
502.2 Calibration Mix #1A (cat.# 30439)
4-bromochlorobenzene (cat.# 30230)
2-chloroethyl vinyl ether (cat.# 30265)
1,4-dichlorobutane (cat.# 30227)
fluorobenzene (cat.# 30030)
methyl tert-butyl ether (MTBE) (cat.# 30402)
Freon 113 (custom)
Conc.:20 ppb in 5 mL of RO water
Injectionpurge and trap splitless
Purge and Trap
Instrument:Tekmar LSC-3000 Purge and Trap
Trap Type:Vocarb 3000
Purge: 11 min, flow 40 mL/min
Dry Purge: 1 min, flow 40 mL/min
Desorb Preheat Temp.:245 °C
Desorb: 2 min @ 250 °C
Bake: 8 min @ 260 °C
Interface Connection:direct
Transfer Line Tubing:0.32mm ID Siltek Guard Column (cat.# 10027)
Oven
Oven Temp.:35 °C (hold 12 min) to 60 °C at 5 °C/min (hold 1 min) to 220 °C at 17 °C/min (hold 3 min)
Carrier GasHe, constant flow
Flow Rate:9 mL/min
DetectorμGold Tandem PID/HALL 2000
NotesDry purge: 1 min. @ 40mL/min. (MCS bypassed with Silcosteel tubing).
PID: makeup 7mL/min., purge 7mL/min., set @ 0.35mV base temp. 200°C.
ELCD Hall 2000: RxnGas 25mL/min.,RxnTemp.: 940°C, propanol flow 470μL/min.
AcknowledgementFinnigan 9001 GC, μGold Tandem Photoionization/HALL 2000 Electrolytic Conductivity Detector provided courtesy of Thermo Finnigan GC & GC/MS Division, 2215 Grand Avenue Pkwy, Austin, Texas 78728
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

8021

,

VOA

,

EPA 8021

,

xylene

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us