share:
delim
delim
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
This chromatogram may contain analytes that are synonyms of your search terms.

Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS

Peaks
1.Dichlorodifluoromethane
2.Chloromethane
3.Vinyl chloride
4.Bromomethane
5.Chloroethane
6.Trichlorofluoromethane
7.1,1-Dichloroethene
8.Carbon disulfide (250ppb)
9.Freon®113
10.Iodomethane
11.Acrolein (250ppb)
12.Allyl chloride
13.Methylene chloride
14.Acetone
15.trans-1,2-Dichloroethene
16.Methyl tert-butyl ether
17.tert-butyl alcohol (250ppb)
18.Chloroprene
19.1,1-Dichloroethane
20.Acrylonitrile
21.Vinyl acetate
22.cis-1,2-Dichloroethene
23.2,2-Dichloropropane
24.Bromochloromethane
25.Chloroform
26.Carbon tetrachloride
27.Tetrahydrofuran (250ppb)
28.Methyl acrylate
29.Ethyl acetate
30.1,1,1-Trichloroethane
31.2-Butanone (250ppb)
32.1,1-Dichloropropene
33.Propionitrile
34.Benzene
35.Methacrylonitrile
36.1,2-dichloroethane-d4
37.1,2-Dichloroethane
38.Isobutyl alcohol (400ppb)
39.Fluorobenzene
40.Isopropyl acetate
41.Trichloroethene
42.Dibromomethane
43.1,2-Dichloropropane
44.Bromodichloromethane
45.Methyl methacrylate
46.1,4-Dioxane (250ppb)
47.n-Propyl acetate
48.2-Chloroethyl vinyl ether
49.cis-1,3-Dichloropropene
50.Toluene-d8
Peaks
51.Toluene
52.4-Methyl-2-pentanone (250ppb)
53.Tetrachloroethene
54.trans-1,3-Dichloropropene
55.2-Bromo-1-chloropropane
56.1,1,2-Trichloroethane
57.Ethyl methacrylate
58.Dibromochloromethane
59.1,3-Dichloropropane
60.1,2-Dibromoethane
61.n-Butyl acetate
62.2-Hexanone (250ppb)
63.Chlorobenzene
64.Ethylbenzene
65.1,1,1,2-Tetrachloroethane
66.m-Xylene
67.p-Xylene
68.1-Chloro-2-fluorobenzene
69.o-Xylene
70.Styrene
71.Bromoform
72.Isopropylbenzene
73.4-Bromo-1-fluorobenzene
74.cis-1,4-Dichloro-2-butene
75.Bromobenzene
76.1,4-Dichlorobutane
77.n-Propylbenzene
78.1,1,2,2-Tetrachloroethane
79.2-Chlorotoluene
80.1,2,3-Trichloropropane
81.1,3,5-Trimethylbenzene
82.trans-1,4-Dichloro-2-butene
83.4-Chlorotoluene
84.tert-Butylbenzene
85.Pentachloroethane
86.1,2,4-Trimethylbenzene
87.sec-Butylbenzene
88.p-Isopropyltoluene
89.1,3-Dichlorobenzene
90.1,4-Dichlorobenzene
91.n-Butylbenzene
92.1,2-Dichlorobenzene-D4
93.1,2-Dichlorobenzene
94.4-Bromo-1-chlorobenzene
95.1,2-Dibromo-3-Chloropropane
96.Nitrobenzene (250ppb)
97.Hexachlorobutadiene
98.1,2,4-Trichlorobenzene
99.Naphthalene
100.1,2,3-Trichlorobenzene
51A.1,1-dichloro-2-propanone (250ppb)
image
GC_EV00423
ColumnRtx-VMS, 60 m, 0.45 mm ID, 2.55 µm (cat.# 19909)
Sample
Conc.:100 ppb in 25 mL of RO water (unless otherwise noted) ketones, acetates, & alcohols in at 2.5x
Injectionpurge and trap split (split ratio 10:1)
Purge and Trap
Instrument:Tekmar LSC-3000 Purge and Trap
Trap Type:Vocarb 3000
Purge: 11 min, flow 40 mL/min
Dry Purge: 1 min, flow 40 mL/min
Desorb Preheat Temp.:245 °C
Desorb: 2 min @ 250 °C, flow 10 mL/min
Bake: 8 min @ 260 °C
Interface Connection:direct
Transfer Line Tubing:0.32mm ID Siltek transfer line
Oven
Oven Temp.:40 °C (hold 7 min) to 50 °C at 9 °C/min to 110 °C at 27 °C/min (hold 1 min) to 225 °C at 40 °C/min (hold 3 min)
Carrier GasHe
DetectorMS
Mode:Scan
Scan Range:35-300 amu
InstrumentHP5890 GC & 5971 MSD
NotesCarrier gas: constant pressure at ~ 10 mL/min.
Adjust dichlorodifluoromethane to a retention time of 1.72 min. @ 40°C.

Dry purge: MCS bypassed using Silcosteel tubing.
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

xylene

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us