EPA Method 524.2, Revision 4 Rtx-VMS
This chromatogram may contain analytes that are synonyms of your search terms.

EPA Method 524.2, Revision 4 Rtx-VMS

PeaksConc. (ppb)
1.Dichlorodifluoromethane
2.Chloromethane
3.Vinyl chloride
4.Bromomethane
5.Chloroethane
6.Trichlorofluoromethane
7.Diethyl ether
8.1,1-Dichloroethene
9.Carbon disulfide40
10.Iodomethane40
11.Allyl chloride
12.Methylene Chloride
13.Acetone
14.trans-1,2-Dichloroethene
15.Methyl tert-butyl ether
16.1,1-Dichloroethane
17.Acrylonitrile
18.cis-1,2-Dichloroethene
19.2,2-Dichloropropane
20.Bromochloromethane
21.Chloroform
22.Methyl acrylate
23.Carbon Tetrachloride
24.Tetrahydrofuran40
25.1,1,1-Trichloroethane
26.2-Butanone
27.1,1-Dichloropropene
28.1-Chlorobutane
29.Benzene
30.Propionitrile
31.1,2-Dichloroethane
32.Fluorobenzene
33.Trichloroethene
34.Dibromomethane
35.1,2-Dichloropropane
36.Bromodichloromethane
37.Methyl methacrylate
38.cis-1,3-Dichloropropene
39.Toluene
40.Chloroacetonitrile
41.2-Nitropropane*
42.1,1-Dichloropropanone*
43.4-Methyl-2-pentanone
PeaksConc. (ppb)
44.Tetrachloroethene
45.trans-1,3-Dichloropropene
46.Ethyl methacrylate
47.1,1,2-Trichloroethane
48.Dibromochloromethane
49.1,3-Dichloropropane
50.1,2-Dibromoethane
51.2-Hexanone
52.Ethylbenzene
53.Chlorobenzene
54.1,1,1,2-Tetrachloroethane
55.m-Xylene
56.p-Xylene
57.o-Xylene
58.Styrene
59.Bromoform
60.Isopropylbenzene
61.4-Bromofluorobenzene
62.n-Propylbenzene
63.Bromobenzene
64.1,1,2,2-Tetrachloroethane
65.1,3,5-Trimethylbenzene
66.2-Chlorotoluene
67.1,2,3-Trichloropropane
68.trans-1,4-Dichloro-2-butene
69.4-Chlorotoluene
70.tert-Butylbenzene
71.1,2,4-Trimethylbenzene
72.Pentachloroethane
73.sec-Butylbenzene
74.p-Isopropyltoluene
75.1,3-Dichlorobenzene
76.1,4-Dichlorobenzene
77.n-Butylbenzene
78.Hexachloroethane
79.1,2-Dichlorobenzene-D4
80.1,2-Dichlorobenzene
81.1,2-Dibromo-3-Chloropropane
82.Nitrobenzene
83.Hexachlorobutadiene
84.1,2,4-Trichlorobenzene
85.Naphthalene
86.1,2,3-Trichlorobenzene
*These peaks (41 and 42) share a quantitation ion (43)
image
GC_EV00430
ColumnRtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Sample502.2 Calibration Mix #1 (gases) (cat.# 30042)
502.2 CAL2000 MegaMix Mixture (cat.# 30431)
524 Calibration Mix #7 Kit (cat.# 30202)
524 Calibration Mix #8 (cat.# 30203)
524 Internal Standard/Surrogate Mix (cat.# 30201)
Conc.: 20ppb in 5mL of RO water (unless otherwise noted); ketones at 40ppb.
Injectionpurge and trap split (split ratio 10:1)
Purge and Trap
Instrument:Tekmar LSC-3000 Purge and Trap
Trap Type:Vocarb 3000
Purge: 11 min, flow 40 mL/min
Dry Purge: 1 min, flow 40 mL/min
Desorb Preheat Temp.:245 °C
Desorb: 2 min @ 250 °C
Bake: 8 min @ 260 °C
Transfer Line Tubing:5m, 0.32mm ID Siltek Guard Column(cat.# 10027)
Oven
Oven Temp.:45 °C (hold 2 min) to 85 °C at 14 °C/min to 210 °C at 40 °C/min (hold 4 min)
Carrier GasHe, constant flow
Flow Rate:1.3 mL/min
DetectorMS
Mode:Scan
Scan Range:35-300 amu
InstrumentHP6890 GC & 5973 MSD
NotesAdjust dichlorodifluoromethane to a retention time of 2.29 min. @ 45°
Dry purge: MCS bypassed
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

EPA Method 524.2

,

Method 524.2

,

524.2

,

Purge and Trap

,

Rtx-VMS

,

Volatiles

,

VOA

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us