share:
delim
delim
Semivolatiles CLP Method on Rtx-5MS
This chromatogram may contain analytes that are synonyms of your search terms.

Semivolatiles CLP Method on Rtx-5MS

PeakstR (min)
1.2-Fluorophenol (SS)4.65
2.Phenol-d6 (SS)5.53
3.Phenol5.55
4.Bis(2-chloroethyl) ether5.64
5.2-Chlorophenol-d4 (SS)5.66
6.2-Chlorophenol5.67
7.1,3-Dichlorobenzene5.81
8.1,4-Dichlorobenzene-d4 (IS)5.86
9.1,4-Dichlorobenzene5.87
10.1,2-Dichlorobenzene-d4 (IS)6.01
11.Benzyl alcohol6.01
12.1,2-Dichlorobenzene6.03
13.2-Methylphenol6.10
14.Bis(2-chloroisopropyl) ether6.13
15.4-Methylphenol/3-Methylphenol6.25
16.N-Nitrosodi-N-propylamine6.28
17.Hexachloroethane6.33
18.Nitrobenzene-d5 (SS)6.41
19.Nitrobenzene6.43
20.Isophorone6.66
21.2-Nitrophenol6.73
22.2,4-Dimethylphenol6.75
23.Bis(2-chloroethoxy)methane6.85
24.Benzoic acid6.91
25.2,4-Dichlorophenol6.95
26.1,2,4-Trichlorobenzene7.03
27.Naphthalene-d8 (IS)7.08
28.Naphthalene7.10
29.4-Chloroaniline7.20
30.Hexachlorobutadiene7.21
31.4-Chloro-3-methylphenol7.62
32.2-Methylnaphthalene7.77
33.Hexachlorocyclopentadiene7.92
34.2,4,6-Trichlorophenol8.05
35.2,4,5-Trichlorophenol8.08
36.2-Fluorobiphenyl (SS)8.13
37.2-Chloronaphthalene8.25
38.2-Nitroaniline8.38
39.Dimethyl phthalate8.54
40.2,6-Dinitrotoluene8.62
PeakstR (min)
41.Acenaphthylene8.66
42.Acenaphthene-d10 (IS)8.79
43.Acenaphthene8.83
44.3-Nitroaniline8.88
45.2,4-Dinitrophenol8.88
46.4-Nitrophenol8.92
47.Dibenzofuran8.99
48.2,4-Dinitrotoluene9.01
49.Diethyl phthalate9.22
50.4-Chlorophenyl phenyl ether9.32
51.Fluorene9.33
52.4-Nitroaniline9.39
53.2-Methyl-4,6-dinitrophenol9.40
54.Diphenylamine9.44
55.2,4,6-Tribromophenol (SS)9.57
56.4-Bromophenyl phenyl ether9.80
57.Hexachlorobenzene9.88
58.Pentachlorophenol10.07
59.Phenanthrene-d10 (IS)10.24
60.Phenanthrene10.27
61.Anthracene10.32
62.Carbazole10.49
63.di-n-Butyl phthalate10.84
64.Fluoranthene11.62
65.Pyrene11.94
66.p-Terphenyl-d14 (SS)12.16
67.Butyl benzyl phthalate13.01
68.Benzo[a]anthracene14.05
69.3,3'-Dichlorobenzidine14.06
70.Chrysene-d12 (IS)14.08
71.Chrysene14.14
72.Bis(2-ethylhexyl)phthalate14.2
73.Di-n-octyl phthalate15.77
74.Benzo[b]fluoranthene16.57
75.Benzo[k]fluoranthene16.64
76.Benzo[a]pyrene17.38
77.Perylene-d12 (IS)17.52
78.Indeno[1,2,3-cd]pyrene20.18
79.Dibenzo[a,h]anthracene20.26
80.Benzo[ghi]perylene20.81
image
GC_EV00544
ColumnRtx-5MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12623)
SampleCLP standard
Conc.:80 ng
Injectionsplitless
Inj. Temp.:300 °C
Oven
Oven Temp.:40 °C (hold 2 min) to 245 °C at 25 °C/min to 330 °C at 6 °C/min (hold 5 min)
Carrier GasHe, constant flow
Flow Rate:1.0 mL/min
DetectorMS
Mode:Scan
Source Temp.:280 °C
Scan Range:35-550 amu
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

semivolatile

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us