This site requires that Javascript be enabled. Please enable Javascript in your browser.
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
This chromatogram may contain analytes that are synonyms of your search terms.
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Peaks tR (min)
1. N-Nitrosodimethylamine 3.38
2. Pyridine 3.37
3. Methyl methanesulfonate 4.53
4. 2-Fluorophenol (SS) 4.61
5. Ethyl methanesulfonate 5.16
6. Phenol 5.51
7. Phenol-d6- (SS) 5.50
8. Aniline 5.52
9. bis(2-chloroethyl)ether 5.58
10. 2-chlorophenol-d4 (SS) 5.60
11. 2-Chlorophenol 5.61
12. 1,3-Dichlorobenzene 5.73
13. 1,4-Dichlorobenzene-D4 (IS) 5.79
14. 1,4-Dichlorobenzene 5.80
15. Benzyl Alcohol 5.96
16. 1,2-Dichlorobenzene-D4 (SS) 5.94
17. 1,2-Dichlorobenzene 5.96
18. 2-Methylphenol 6.06
19. Bis(2-Chloroisopropyl)ether 6.06
20. 4-Methylphenol/3-Methylphenol 6.22
21. N-Nitrosodi-N-propylamine 6.24
22. Acetophenone 6.20
23. Hexachloroethane 6.25
24. Nitrobenzene-D5 (SS) 6.35
25. Nitrobenzene 6.37
26. Isophorone 6.59
27. 2,4-Dimethylphenol 6.70
28. 2-Nitrophenol 6.66
29. Benzoic acid 6.87
30. Bis(2-chloroethoxy)methane 6.79
31. 2,4-Dichlorophenol 6.89
32. 1,2,4-Trichlorobenzene 6.95
33. Naphthalene-D8 (IS) 7.00
34. Naphthalene 7.03
35. 2,6-Dichlorophenol 7.10
36. 4-Chloroaniline 7.12
37. Hexachloropropene 7.10
38. Hexachlorobutadiene 7.14
39. 4-Chloro-3-methylphenol 7.57
40. Isosafrole 7.61
41. 2-Methylnaphthalene 7.69
42. 1-Methylnaphthalene 7.79
43. Hexachlorocyclopentadiene 7.85
44. 1,2,4,5-Tetrachlorobenzene 7.86
45. 2,4,6-Trichlorophenol 7.98
46. 2,4,5-Trichlorophenol 8.02
47. 2-Fluorobiphenyl (SS) 8.05
48. Safrole 8.11
49. 2-Chloronaphthalene 8.17
50. 2-Nitroaniline 8.32
51. 1,4-Naphthoquinone 8.37
52. Dimethyl phthalate 8.48
53. 1,3-Dinitrobenzene 8.54
Peaks tR (min)
54. 2,6-Dinitrotoluene 8.56
55. Acenaphthylene 8.57
56. 3-Nitroaniline 8.68
57. Acenaphthene-d10 (IS) 8.71
58. Acenaphthene 8.74
59. 2,4-Dinitrophenol 8.82
60. 4-Nitrophenol 8.91
61. Pentachlorobenzene 8.89
62. 2,4-Dinitrotoluene 8.94
63. Dibenzofuran 8.91
64. 2,3,4,6-Tetrachlorophenol 9.05
65. Diethyl Phthalate 9.15
66. 4-Chlorophenyl phenyl ether 9.24
67. Fluorene 9.24
68. 4-Nitroaniline 9.30
69. 4,6-Dinitro-2-methylphenol 9.33
70. Diphenylamine 9.37
71. Azobenzene 9.39
72. 2,4,6-Tribromophenol (SS) 9.49
73. Phenacetin 9.70
74. 4-Bromophenyl phenyl ether 9.71
75. Hexachlorobenzene 9.80
76. Pentachlorophenol 9.99
77. Pentachloronitrobenzene 10.02
78. Dinoseb 10.16
79. Phenanthrene-D10 (IS) 10.16
80. Phenanthrene 10.18
81. Anthracene 10.23
82. di-n- Butyl phthalate 10.75
83. 4-nitroquinoline-1-oxide 11.04
84. Isodrin 11.29
85. Fluoranthene 11.50
86. Benzidine 11.71
87. Pyrene 11.80
88. Aramite 12.10
89. p- Terphenyl-d14 (SS)12.02
90. Chlorbenzilate 12.31
91. Butyl benzyl phthalate 12.84
92. Kepone 12.81
93. Bis(2-ethylhexyl)phthalate 13.99
94. Chrysene-D12 (IS) 13.87
95. 3,3'-Dichlorobenzidine 13.87
96. Benzo[a]anthracene (IS) 13.84
97. Chrysene 13.93
98. Di-n- octyl phthalate 15.51
99. Benzo[b]fluoranthene 16.29
100. Benzo[k]fluoranthene 16.35
101. Benzo[a]pyrene 17.07
102. Perylene-D12 (IS) 17.22
103. 3-Methylcholanthrene 17.98
104. Indeno[1,2,3-cd]pyrene 19.82
105. Dibenzo[a,h]anthracene 19.91
106. Benzo[ghi]perylene 20.44
GC_EV00545
Rtx-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12723) Semivolatiles 8270 Standard
80 ng splitless 300 °C 40 °C (hold 2 min) to 245 °C at 25 °C/min to 330 °C at 6 °C/min (hold 5 min) He, constant flow 1.0 mL/min MS Scan 280 °C 35-550 amu
Download PDF RELATED CHROMATOGRAM LIBRARY SEARCHES
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy .