share:
delim
delim
Volatile Organics US EPA Method 8260B on Rtx-VMS
This chromatogram may contain analytes that are synonyms of your search terms.

Volatile Organics US EPA Method 8260B on Rtx-VMS

Peaks
1.Carbon dioxide
2.Dichlorodifluoromethane
3.Freon® 114
4.Chloromethane
5.Vinyl chloride
6.Bromomethane
7.Chloroethane
8.Trichlorofluoromethane
9.Ethanol
10.Diethyl ether
11.1,1-Dichloroethene
12.Iodomethane
13.Carbon disulfide
14.Freon® 113
15.Acrolein
16.Allyl chloride
17.Methylene Chloride
18.Acetone
19.trans-1,2-Dichloroethene
20.Methyl acetate
21.Methyl tert-butyl ether
22.tert-Butyl Alcohol
23.Acetonitrile
24.Diisopropyl ether
25.Chloroprene
26.1,1-Dichloroethane
27.Acrylonitrile
28.vinyl acetate**
29.Ethyl- tert-butyl ether**
30.cis-1,2-Dichloroethene
31.2,2-Dichloropropane
32.Bromochloromethane
33.Chloroform
34.Carbon Tetrachloride
35.Ethyl Acetate
36.Methyl acrylate
37.Dibromofluoromethane
38.Tetrahydrofuran
39.1,1,1-Trichloroethane
40.2-Butanone
41.1,1-Dichloropropene
42.Benzene
43.Propionitrile
44.Methacrylonitrile
45.Pentafluorobenzene
46.tert-Amyl Methyl ether
47.1,2-Dichloroethane
48.Isobutyl alcohol
49.Isopropyl acetate
50.Trichloroethene
51.1,4-Difluorobenzene
52.Dibromomethane
53.1,2-Dichloropropane
54.Bromodichloromethane
55.Methyl methacrylate
Peaks
56.n-Propyl acetate
57.2-Chloroethyl vinyl ether
58.cis-1,3-Dichloropropene
59.Toluene-D8
60.Toluene
61.2-Nitropropane
62.Tetrachloroethene
63.4-Methyl-2-pentanone
64.trans-1,3-Dichloropropene
65.2-Bromo-1-chloropropane
66.1,1,2-Trichloroethane
67.Ethyl methacrylate
68.Dibromochloromethane
69.1,3-Dichloropropane
70.1,2-Dibromoethane
71.n-Butyl acetate
72.2-Hexanone
73.Chlorobenzene-d5
74.Chlorobenzene
75.Ethylbenzene
76.1,1,1,2-Tetrachloroethane
77.m-Xylene
78.p-Xylene
79.o-Xylene
80.Styrene
81.Bromoform
82.Isopropylbenzene
83.n-Amyl acetate
84.4-bromo-1-fluorobenzene (ss)
85.cis-1,4-dichloro-2-butene
86.n-Propylbenzene
87.Bromobenzene
88.1,4-Dichlorobutane
89.1,1,2,2-Tetrachloroethane
90.2-Chlorotoluene
91.1,3,5-Trimethylbenzene
92.1,2,3-Trichloropropane
93.trans-1,4-Dichloro-2-butene
94.4-Chlorotoluene
95.tert-Butylbenzene
96.Pentachloroethane
97.1,2,4-Trimethylbenzene
98.sec-Butylbenzene
99.p-Isopropyltoluene
100.1,3-Dichlorobenzene
101.1,4-Dichlorobenzene-D4
102.1,4-Dichlorobenzene
103.n-Butylbenzene
104.1,2-Dichlorobenzene
105.1,2-Dibromo-3-Chloropropane
106.Nitrobenzene
107.Hexachlorobutadiene
108.1,2,4-Trichlorobenzene
109.Naphthalene
110.1,2,3-Trichlorobenzene
*2-Chloroethanol in 8260B mix requires lower scan range for identification; 1,4-dioxane requires fortification or identification using single point high calibration standard. **Peaks 28 & 29 share ion (43).
image
GC_EV00640
ColumnRtx-VMS, 40 m, 0.18 mm ID, 1.00 µm (cat.# 49915)
Sample8260B MegaMix Calibration Mix Kit (cat.# 30475)
502.2 Calibration Mix #1 (gases) (cat.# 30042)
VOA Calibration Mix #1 (ketones) (cat.# 30006)
8260 Internal Standard Mix (cat.# 30074)
8260 Surrogate Mix (cat.# 30073)
8260B Acetate Mix (Revised) (cat.# 30489)
California Oxygenates Mix (cat.# 30465)
acrolein (cat.# 30478)
ethanol (cat.# 30466)
1,2-dichlorotetrafluoroethane (CFC-114) (cat.# 30476)
Diluent:25 mL RO water
Conc.: 5ppb each
Injectionpurge and trap split (split ratio 40:1)
Liner:1mm Split (cat.# 20972)
Inj. Temp.:250 °C
Purge and Trap
Instrument:Tekmar LSC3100 Purge and Trap
Trap Type:Vocarb 3000
Purge: 11 min, flow 40 mL/min
Dry Purge: 1 min, flow 40 mL/min
Desorb Preheat Temp.:245 °C
Desorb: 2 min @ 250 °C, flow 45 mL/min
Bake: 8 min @ 260 °C
Interface Connection:injection port
Transfer Line Tubing:Silcosteel transfer line
Oven
Oven Temp.:35 °C (hold 2 min) to 60 °C at 4 °C/min to 225 °C at 40 °C/min (hold 5 min)
Carrier GasHe, constant flow
Flow Rate:1.1 mL/min
Detector5973 GC/MS w/ turbomolecular pump
Source Temp.:280 °C
Ionization Mode:EI
Scan Range:35-260 amu
NotesMCS by-passed with Silcosteel tubing, cat.# 21035
Download PDF

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us