This site requires that Javascript be enabled. Please enable Javascript in your browser.
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
This chromatogram may contain analytes that are synonyms of your search terms.
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Peaks
1. 1,4-Dioxane
2. N-Nitrosodimethylamine
3. Pyridine
4. 2-Fluorophenol (SS)
5. Phenol-d6 (SS)
6. Phenol
7. Aniline
8. Bis(2-chloroethyl) ether
9. 2-Chlorophenol
10. 1,3-Dichlorobenzene
11. 1,4-Dichlorobenzene-d4 (IS)
12. 1,4-Dichlorobenzene
13. Benzyl alcohol
14. 1,2-Dichlorobenzene
15. 2-Methylphenol
16. Bis(2-chloroisopropyl) ether
17. 4-Methylphenol/3-methylphenol
18. N-Nitrosodi-N-propylamine
19. Hexachloroethane
20. Nitrobenzene-d5 (SS)
21. Nitrobenzene
22. Isophorone
23. 2-Nitrophenol
24. 2,4-Dimethylphenol
25. Benzoic acid
26. Bis(2-chloroethoxy)methane
27. 2,4-Dichlorophenol
28. 1,2,4-Trichlorobenzene
29. Naphthalene-d8 (IS)
30. Naphthalene
31. 4-Chloroaniline
32. Hexachlorobutadiene
33. 4-Chloro-3-methylphenol
34. 2-Methylnaphthalene
35. 1-Methylnaphthalene
36. Hexachlorocyclopentadiene
37. 2,4,6-Trichlorophenol
38. 2,4,5-Trichlorophenol
39. 2-Fluorobiphenyl (SS)
40. 2-Chloronaphthalene
41. 2-Nitroaniline
42. 1,4-Dinitrobenzene
43. Dimethyl phthalate
44. 1,3-Dinitrobenzene
45. 2,6-Dinitrotoluene
46. 1,2-Dinitrobenzene
Peaks
47. Acenaphthylene
48. 3-Nitroaniline
49. Acenaphthene-d10 (IS)
50. Acenaphthene
51. 2,4-Dinitrophenol
52. 4-Nitrophenol
53. 2,4-Dinitrotoluene
54. Dibenzofuran
55. 2,3,5,6-Tetrachlorophenol
56. 2,3,4,6-Tetrachlorophenol
57. Diethyl phthalate
58. 4-Chlorophenyl phenyl ether
59. Fluorene
60. 4-Nitroaniline
61. 4,6-Dinitro-2-methylphenol
62. n- Nitroso-diphenylamine (diphenylamine)
63. 1,2-Diphenylhydrazine (as azobenzene)
64. 2,4,6-Tribromophenol (SS)
65. 4-Bromophenyl phenyl ether
66. Hexachlorobenzene
67. Pentachlorophenol
68. Phenanthrene-d10 (IS)
69. Phenanthrene
70. Anthracene
71. Carbazole
72. di-n- Butyl phthalate
73. Fluoranthene
74. Benzidine
75. Pyrene-d10 (SS)
76. Pyrene
77. p- Terphenyl-d14 (SS)
78. 3,3'-Dimethylbenzidine
79. Butyl benzyl phthalate
80. Bis(2-ethylhexyl) adipate
81. 3,3'-Dichlorobenzidine
82. Benzo[a]anthracene
83. Bis(2-ethylhexyl)phthalate
84. Chrysene-d12 (IS)
85. Chrysene
86. Di-n- octyl phthalate
87. Benzo[b]fluoranthene
88. Benzo[k]fluoranthene
89. Benzo[a]pyrene
90. Perylene-d12 (IS)
91. Indeno[1,2,3-cd]pyrene
92. Dibenzo[a,h]anthracene
93. Benzo[ghi]perylene
c = contaminant (toluene)
GC_EV00943
Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623) 8270 MegaMix (cat.# 31850) Benzoic acid (cat.# 31879) 8270 Benzidines mix (cat.# 31852) Acid surrogate mix (4/89 SOW) (cat.# 31025) Revised B/N surrogate mix (cat.# 31887) 1,4-Dioxane (cat.# 31853) SV internal standard mix (cat.# 31206)
10 µg/mL (IS 40 μg/mL) 1.0 µL pulsed splitless (hold 0.15 min) 4 mm drilled Uniliner (hole near bottom) (cat.# 20756) 250 °C 25 psi (172.4kPa) 0.2 min 60 mL/min 40 °C (hold 1.0 min) to 280 °C at 25 °C/min to 320 °C at 5 °C/min (hold 1 min) He, constant flow 1.2 mL/min MS Scan 280 °C EI 35-550 amu
Download PDF RELATED CHROMATOGRAM LIBRARY SEARCHES
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy .