Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
This chromatogram may contain analytes that are synonyms of your search terms.
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Peaks
1. 1,4-Dioxane
2. N-Nitrosodimethylamine
3. Pyridine
4. 2-Fluorophenol (SS)
5. Phenol-d6- (SS)
6. Phenol
7. Aniline
8. Bis(2-chloroethyl) ether
9. 2-Chlorophenol
10. 1,3-Dichlorobenzene
11. 1,4-dichlorobenzene-d4 (IS)
12. 1,4-Dichlorobenzene
13. Benzyl alcohol
14. 2-Methylphenol
15. 1,2-Dichlorobenzene
16. Bis(2-chloroisopropyl) ether
17. 4-methylphenol/3-methylphenol
18. N-Nitrosodi-N-propylamine
19. Hexachloroethane
20. nitrobenzene-d5 (SS)
21. Nitrobenzene
22. Isophorone
23. 2,4-Dimethylphenol
24. Benzoic acid
25. 2-Nitrophenol
26. Bis(2-chloroethoxy)methane
27. 2,4-Dichlorophenol
28. 1,2,4-Trichlorobenzene
29. Naphthalene-d8 (IS)
30. Naphthalene
31. 4-Chloroaniline
32. Hexachlorobutadiene
33. 4-Chloro-3-methylphenol
34. 2-Methylnaphthalene
35. 1-Methylnaphthalene
36. Hexachlorocyclopentadiene
37. 2,4,6-Trichlorophenol
38. 2,4,5-Trichlorophenol
39. 2-Fluorobiphenyl (SS)
40. 2-Chloronaphthalene
41. 2-Nitroaniline
42. 1,4-Dinitrobenzene
43. Dimethyl phthalate
44. 1,3-Dinitrobenzene
45. 2,6-Dinitrotoluene
46. 1,2-Dinitrobenzene
Peaks
47. Acenaphthylene
48. 3-Nitroaniline
49. acenaphthene-d10 (IS)
50. 2,4-Dinitrophenol
51. Acenaphthene
52. 4-Nitrophenol
53. 2,4-Dinitrotoluene
54. Dibenzofuran
55. 2,3,5,6-Tetrachlorophenol
56. 2,3,4,6-Tetrachlorophenol
57. Diethyl phthalate
58. 4-Chlorophenyl phenyl ether
59. 4-Nitroanaline
60. Fluorene
61. 4,6-Dinitro-2-methylphenol
62. n- Nitroso-diphenylamine (diphenylamine
63. 1,2-Diphenylhydrazine (as azobenzene)
64. 2,4,6-Tribromophenol (SS)
65. 4-Bromophenyl phenyl ether
66. Hexachlorobenzene
67. Pentachlorophenol
68. Phenanthrene-d10 (IS)
69. Phenanthrene
70. Anthracene
71. Carbazole
72. di-n- Butyl phthalate
73. Fluoranthene
74. Benzidine
75. Pyrene-d10 (SS)
76. 3,3'-Dimethylbenzidine
77. Pyrene
78. p- terphenyl-d14 (SS)
79. Butyl benzyl phthalate
80. Bis(2-ethylhexyl) adipate
81. Bis(2-ethylhexyl)phthalate
82. 3,3'-Dichlorobenzidine
83. Benzo[a]anthracene
84. Chrysene-d12 (IS)
85. Chrysene
86. Di-n- octyl phthalate
87. Benzo[b]fluoranthene
88. Benzo[k]fluoranthene
89. Benz[a]pyrene
90. Perylene-d12 (IS)
91. Dibenzo[a,h]anthracene
92. Indeno[1,2,3-cd]pyrene
93. Benzo[ghi]perylene
GC_EV00944
Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.50 µm (cat.# 13638) 8270 MegaMix (cat.# 31850) benzoic acid (cat.# 31879) 8270 Benzidines Mix (cat.# 31852) Acid Surrogate Mix (4/89 SOW) (cat.# 31025) Revised B/N Surrogate Mix (cat.# 31887) 1,4-Dioxane (cat.# 31853) SV Internal Standard Mix (cat.# 31206)
10 ng on-column concentration 1.0 µL pulsed splitless (hold 0.25 min) Drilled Uniliner (hole near bottom) (cat.# 20756) 250 °C 30 psi (206.8kPa) 0.3 min 40 mL/min 40 °C (hold 1.0 min) to 280 °C at 25 °C/min to 320 °C at 5 °C/min (hold 3.5 min) He, constant flow 1.2 mL/min MS Scan 280 °C EI 35-550 amu