This site requires that Javascript be enabled. Please enable Javascript in your browser.
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
This chromatogram may contain analytes that are synonyms of your search terms.
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
Peaks
1. Dichlorodifluoromethane
2. Chlorodifluoromethane
3. Chloromethane
4. Vinyl chloride
5. 1,3-Butadiene
6. Bromomethane
7. Trichlorofluoromethane
8. Diethyl ether
9. 1,1-Dichloroethene
10. Carbon disulfide
11. Methyl iodide
12. Allyl chloride
13. Methylene chloride
14. trans- 1,2-Dichloroethene
15. Methyl acetate
16. MTBE-D3 (SS)
17. MTBE
18. tert- Butyl alcohol (TBA)
19. Diisopropyl ether (DIPE)
20. 1,1-Dichloroethane
21. tert- Butyl ethyl ether (ETBE)
22. cis- 1,2-Dichloroethene
23. Bromochloromethane
24. Chloroform
25. Carbon tetrachloride
26. Tetrahydrofuran
27. 1,1,1-Trichloroethane
28. 1,1-Dichloropropene
29. 1-Chlorobutane
30. Benzene
31. tert- Amyl methyl ether (TAME)
32. 1,2-Dichloroethane
33. Trichloroethene
34. 1,4-Difluorobenzene
35. tert- Amyl ethyl ether (TAEE)
36. Dibromomethane
37. 1,2-Dichloropropane
38. Bromodichloromethane
39. cis- 1,3-Dichloropropene
40. Toluene
41. Tetrachloroethene
Peaks
42. trans- 1,3-Dichloropropene
43. 1,1,2-Trichloroethane
44. Ethyl methacrylate
45. Dibromochloromethane
46. 1,3-Dichloropropane
47. 1,2-Dibromoethane
48. Chlorobenzene-D5
49. Chlorobenzene
50. Ethylbenzene
51. 1,1,1,2-Tetrachloroethane
52. m- Xylene
53. p- Xylene
54. o- Xylene
55. Styrene
56. Bromoform
57. Isopropylbenzene
58. 4-Bromofluorobenzene (SS)
59. Bromobenzene
60. n- Propylbenzene
61. 1,1,2,2-Tetrachloroethane
62. 2-Chlorotoluene
63. 1,3,5-Trimethylbenzene
64. 1,2,3-Trichloropropane
65. 4-Chlorotoluene
66. tert- Butylbenzene
67. Pentachloroethane
68. 1,2,4-Trimethylbenzene
69. sec- Butylbenzene
70. 4-Isopropyltoluene
71. 1,3-Dichlorobenzene
72. 1,4-Dichlorobenzene-D4
73. 1,4-Dichlorobenzene
74. n- Butylbenzene
75. Hexachloroethane
76. 1,2-Dichlorobenzene-D4 (SS)
77. 1,2-Dichlorobenzene
78. 1,2-Dibromo-3-chloropropane
79. Hexachlorobutadiene
80. 1,2,4-Trichlorobenzene
81. Naphthalene
82. 1,2,3-Trichlorobenzene
GC_EV1297
Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) 524.3 internal standard/surrogate mix (cat.# 30017) 524.3 gas calibration mix (cat.# 30014) 524.3 VOA MegaMix standard (cat.# 30013)
RO water 5 ng/mL (5 mL sample) purge and trap split (split ratio 30:1) Premium 1.0mm ID straight inlet liner (cat.# 23333.1) 200 °C EST Encon Evolution Vocarb 3000 11 min, flow 40 mL/min 1 min, flow 50 mL/min 1 min @ 260 °C, flow 30.9 mL/min 8 min @ 265 °C injection port 150 °C 45 °C (hold 4.5 min) to 100 °C at 12 °C/min to 240 °C at 25 °C/min (hold 1.32 min) He, constant flow 0.9 mL/min MS Scan Group Start Time (min) Scan Range (amu) Scan Rate (scans/sec) 1 1.5 47–300 5.4 2 2.9 35–300 5.19
240 °C Quadrupole 230 °C 150 °C 70 eV 1.5 min BFB EI Agilent 7890A GC & 5975C MSD EST Analytical provided the Centurion robotic autosampler and Encon Evolution P&T concentrator.
Download PDF RELATED CHROMATOGRAM LIBRARY SEARCHES
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy .