This site requires that Javascript be enabled. Please enable Javascript in your browser.
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
This chromatogram may contain analytes that are synonyms of your search terms.
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Peaks
1. 1,4-Dioxane-d8 (IS)
2. 1,4-Dioxane
3. N-Nitrosodimethylamine
4. Pyridine
5. Ethyl methacrylate
6. 2-Picoline
7. N-Nitrosomethylethylamine
8. Methyl methanesulfonate
9. 2-Fluorophenol (SS)
10. N-Nitrosodiethylamine
11. Ethyl methanesulfonate
12. Benzaldehyde
13. Phenol-d6 (SS)
14. Phenol
15. Aniline
16. Pentachloroethane
17. Bis(2-chloroethyl) ether
18. 2-Chlorophenol
19. 1,3-Dichlorobenzene
20. 1,4-Dichlorobenzene-d4 (IS)
21. 1,4-Dichlorobenzene
22. Benzyl alcohol
23. 1,2-Dichlorobenzene
24. 2-Methylphenol
25. Bis(2-Chloroisopropyl)ether
26. p- Cresol (4-methylphenol)
27. m- Cresol (3-methylphenol)
28. N-Nitrosopyrrolidine
29. Acetophenone
30. N-Nitrosodi-n- propylamine
31. 4-Nitrosomorpholine
32. o- Toluidine
33. Hexachloroethane
34. Nitrobenzene-d5 (SS)
35. Nitrobenzene
36. N-Nitrosopiperidine
37. Isophorone
38. 2-Nitrophenol
39. 2,4-Dimethylphenol
40. Benzoic acid
41. Bis(2-chloroethoxy)methane
42. 2,4-Dichlorophenol
43. α,α-Dimethylphenethylamine (Phentermine)
44. 1,2,4-Trichlorobenzene
45. Naphthalene-d8 (IS)
46. Naphthalene
47. 4-Chloroaniline
48. 2,6-Dichlorophenol
49. Hexachloropropene
50. Hexachlorobutadiene
51. Caprolactam
52. N-Nitroso-N-butylamine
53. 1,4-Phenylenediamine
54. 4-Chloro-3-methylphenol
55. Isosafrole I (isomer)
56. 2-Methylnaphthalene
57. 1-Methylnaphthalene
58. Isosafrole II (isomer)
59. 1,2,4,5-Tetrachlorobenzene
60. Hexachlorocyclopentadiene
61. 2,4,6-Trichlorophenol
62. 2,4,5-Trichlorophenol
63. 2-Fluorobiphenyl (SS)
64. Safrole
65. Biphenyl
66. 2-Chloronaphthalene
67. 1-Chloronaphthalene
68. Diphenyl ether
69. 2-Nitroaniline
70. 1,4-Naphthoquinone
71. 1,4-Dinitrobenzene
72. Dimethyl phthalate
Peaks
73. 1,3-Dinitrobenzene
74. 2,6-Dinitrotoluene
75. Acenaphthylene
76. 1,2-Dinitrobenzene
77. 3-Nitroaniline
78. Acenaphthene-d10 (IS)
79. Acenaphthene
80. 2,4-Dinitrophenol
81. 4-Nitrophenol
82. Dibenzofuran
83. 2,4-Dinitrotoluene
84. Pentachlorobenzene
85. 1-Naphthalamine
86. 2,3,5,6-Tetrachlorophenol
87. 2-Naphthalamine
88. 2,3,4,6-Tetrachlorophenol
89. Diethyl phthalate
90. 4-Chlorophenyl phenyl ether
91. Fluorene
92. 2-Methyl-5-nitroaniline
93. 4-Nitroaniline
94. 4,6-Dinitro-2-methylphenol
95. N-Nitrosodiphenylamine
96. 1,2-Diphenylhydrazine (as Azobenzene)
97. 2,4,6-Tribromophenol (SS)
98. 1,3,5-Trinitrobenzene
99. Diallate
100. Phenacetin
101. 4-Bromophenyl phenyl ether
102. Hexachlorobenzene
103. Atrazine
104. 4-Aminobiphenyl
105. Pentachlorophenol
106. Propyzamide
107. Pentachloronitrobenzene
108. Phenanthrene-d10 (IS)
109. Phenanthrene
110. Anthracene
111. Carbazole
112. di-n- Butyl phthalate
113. 4-Nitroquinoline oxide
114. Isodrin
115. Fluoranthene
116. Benzidine
117. Pyrene-d10 (SS)
118. Pyrene
119. Aramite I (isomer)
120. p- Terphenyl-d14 (SS)
121. Aramite II (isomer)
122. Dimethylaminoazobenzene
123. Chlorobenzilate
124. 3,3'-Dimethylbenzidine
125. Butyl benzyl phthalate
126. Kepone
127. Bis(2-ethylhexyl) adipate
128. 2-Acetylaminofluorine
129. 3,3'-Dichlorobenzidine
130. Benz[a]anthracene
131. Chrysene-d12 (IS)
132. Chrysene
133. Bis(2-ethylhexyl) phthalate
134. Di-n- octyl phthalate
135. Benzo[b]fluoranthene
136. 7,12-Dimethylbenzo[a]anthracene
137. Benzo[k]fluoranthene
138. Benzo[a]pyrene
139. Perylene-d12 (IS)
140. 3-Methylcholanthrene
141. Dibenz[a,j]acridine
142. Indeno[1,2,3-cd]pyrene
143. Dibenz[a,h]anthracene
144. Benzo[ghi]perylene
GC_EV1304
Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423) Revised SV internal standard mix (cat.# 31886) Revised B/N surrogate mix (cat.# 31888) Acid surrogate mix (4/89 SOW) (cat.# 31063) 8270 MegaMix (cat.# 31850) 8270 Benzidines mix (cat.# 31852) Benzoic acid (cat.# 31879) Appendix IX mix #1, revised (cat.# 32459) Appendix IX mix #2 (cat.# 31806)
Dichloromethane 10 µg/mL (IS/SS 20 µg/mL) 1 µL split (split ratio 10:1) Premium 4 mm Precision liner w/wool (cat.# 23305.5) 275 °C 14.4 mL/min 50 °C (hold 0.5 min) to 265 °C at 28 °C/min to 285 °C at 3 °C/min to 330 °C at 25 °C/min (hold 1 min) He, constant flow 1.44 mL/min MS Scan Group Start Time (min) Scan Range (amu) Scan Rate (scans/sec) 1 1.35 35-550 5.36
290 °C Quadrupole 330 °C 180 °C 70 eV 1.35 min DFTPP EI Agilent 7890A GC & 5975C MSD
Download PDF RELATED CHROMATOGRAM LIBRARY SEARCHES
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy .