9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
This chromatogram may contain analytes that are synonyms of your search terms.
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Peaks
1.
1,4-Dioxane-d8 (IS)
2.
1,4-Dioxane
3.
N-Nitrosodimethylamine
4.
Pyridine
5.
Ethyl methacrylate
6.
2-Picoline
7.
N-Nitrosomethylethylamine
8.
Methyl methanesulfonate
9.
2-Fluorophenol (SS)
10.
N-Nitrosodiethylamine
11.
Ethyl methanesulfonate
12.
Benzaldehyde
13.
Phenol-d6 (SS)
14.
Phenol
15.
Aniline
16.
Pentachloroethane
17.
Bis(2-chloroethyl) ether
18.
2-Chlorophenol
19.
1,3-Dichlorobenzene
20.
1,4-Dichlorobenzene-d4 (IS)
21.
1,4-Dichlorobenzene
22.
Benzyl alcohol
23.
1,2-Dichlorobenzene
24.
2-Methylphenol
25.
Bis(2-Chloroisopropyl)ether
26.
p-Cresol (4-methylphenol)
27.
m-Cresol (3-methylphenol)
28.
Acetophenone
29.
N-Nitrosopyrrolidine
30.
N-Nitrosomorpholine
31.
N-Nitrosodi-n-propylamine
32.
o-Toluidine
33.
Hexachloroethane
34.
Nitrobenzene-d5 (SS)
35.
Nitrobenzene
36.
N-Nitrosopiperidine
37.
Isophorone
38.
2-Nitrophenol
39.
2,4-Dimethylphenol
40.
Bis(2-chloroethoxy)methane
41.
Benzoic acid
42.
2,4-Dichlorophenol
43.
α,α-Dimethylphenethylamine (Phentermine)
44.
1,2,4-Trichlorobenzene
45.
Naphthalene-d8 (IS)
46.
Naphthalene
47.
4-Chloroaniline
48.
2,6-Dichlorophenol
49.
Hexachloropropene
50.
Hexachlorobutadiene
51.
Caprolactam
52.
N-Nitroso-n-butylamine
53.
1,4-Phenylenediamine
54.
4-Chloro-3-methylphenol
55.
Isosafrole I (isomer)
56.
2-Methylnaphthalene
57.
1-Methylnaphthalene
58.
Isosafrole II (isomer)
59.
1,2,4,5-Tetrachlorobenzene
60.
Hexachlorocyclopentadiene
61.
2,4,6-Trichlorophenol
62.
2,4,5-Trichlorophenol
63.
2-Fluorobiphenyl (SS)
64.
Safrole
65.
Biphenyl
66.
2-Chloronaphthalene
67.
1-Chloronaphthalene
68.
Diphenyl ether
69.
2-Nitroaniline
70.
1,4-Naphthoquinone
71.
1,4-Dinitrobenzene
72.
Dimethyl phthalate
Peaks
73.
1,3-Dinitrobenzene
74.
2,6-Dinitrotoluene
75.
Acenaphthylene
76.
1,2-Dinitrobenzene
77.
3-Nitroaniline
78.
Acenaphthene-d10 (IS)
79.
Acenaphthene
80.
2,4-Dinitrophenol
81.
4-Nitrophenol
82.
Dibenzofuran
83.
Pentachlorobenzene
84.
2,4-Dinitrotoluene
85.
1-Naphthalamine
86.
2,3,5,6-Tetrachlorophenol
87.
2-Naphthalamine
88.
2,3,4,6-Tetrachlorophenol
89.
Diethyl phthalate
90.
4-Chlorophenyl phenyl ether
91.
Fluorene
92.
2-Methyl-5-nitroaniline
93.
4-Nitroaniline
94.
4,6-Dinitro-2-methylphenol
95.
N-Nitrosodiphenylamine
96.
1,2-Diphenylhydrazine (as Azobenzene)
97.
2,4,6-Tribromophenol (SS)
98.
1,3,5-Trinitrobenzene
99.
Diallate
100.
Phenacetin
101.
4-Bromophenyl phenyl ether
102.
Hexachlorobenzene
103.
Atrazine
104.
4-Aminobiphenyl
105.
Pentachlorophenol
106.
Propyzamide
107.
Pentachloronitrobenzene
108.
Phenanthrene-d10 (IS)
109.
Phenanthrene
110.
Anthracene
111.
Carbazole
112.
di-n-Butyl phthalate
113.
4-Nitroquinoline oxide
114.
Isodrin
115.
Fluoranthene
116.
Benzidine
117.
Pyrene-d10 (SS)
118.
Pyrene
119.
Aramite I (isomer)
120.
p-Terphenyl-d14 (SS)
121.
Aramite II (isomer)
122.
Dimethylaminoazobenzene
123.
Chlorobenzilate
124.
3,3'-Dimethylbenzidine
125.
Kepone
126.
n-Butyl benzyl phthalate
127.
Bis(2-ethylhexyl) adipate
128.
2-Acetylaminofluorine
129.
3,3'-Dichlorobenzidine
130.
Chrysene-d12 (IS)
131.
Benz[a]anthracene
132.
Chrysene
133.
Bis(2-ethylhexyl) phthalate
134.
Di-n-octyl phthalate
135.
Benzo[b]fluoranthene
136.
Benzo[k]fluoranthene
137.
7,12-Dimethylbenzo[a]anthracene
138.
Benzo[a]pyrene
139.
Perylene-d12 (IS)
140.
3-Methylcholanthrene
141.
Dibenz[a,j]acridine
142.
Indeno[1,2,3-cd]pyrene
143.
Dibenz[a,h]anthracene
144.
Benzo[ghi]perylene
GC_EV1328
Column
Rxi-5ms, 10 m, 0.18 mm ID, 0.18 µm
using Rxi-5ms 2 m, 0.18 mm ID,
with 0.4 mm OD matched press-fit, BGB (cat.# 2525LD)
Sample
Revised SV internal standard mix (cat.# 31886)
Revised B/N surrogate mix (cat.# 31888)
Acid surrogate mix (4/89 SOW) (cat.# 31063)
8270 MegaMix (cat.# 31850)
8270 Benzidines mix (cat.# 31852)
Benzoic acid (cat.# 31879)
Appendix IX mix #1, revised (cat.# 32459)
Appendix IX mix #2 (cat.# 31806)
Diluent:
Dichloromethane
Conc.:
20 µg/mL (1.0 ng on column)
Injection
Inj. Vol.:
0.5 µL split (split ratio 10:1)
Liner:
2 mm Split Precision liner w/deact. wool (cat.# 20824)
Inj. Temp.:
275 °C
Split Vent Flow Rate:
9 mL/min
Oven
Oven Temp.:
35 °C (hold 0.5 min) to 115 °C at 95 °C/min to 240 °C at 65 °C/min to 265 °C at 6 °C/min to 330 °C at 35 °C/min (hold 1 min)
Carrier Gas
He, constant flow
Flow Rate:
0.9 mL/min
Detector
MS
Mode:
Scan
Scan Program:
Group
Start Time (min)
Scan Range (amu)
Scan Rate (scans/sec)
1
0.75
35-450
11.47
2
3.67
35-450
6.48
Transfer Line Temp.:
320 °C
Analyzer Type:
Quadrupole
Source Type:
Inert
Drawout Plate:
3mm ID
Source Temp.:
330 °C
Quad Temp.:
180 °C
Electron Energy:
70 eV
Solvent Delay Time:
0.75 min
Tune Type:
BFB
Ionization Mode:
EI
Instrument
Agilent 7890A GC & 5975C MSD
Notes
The 10 m analytical and 2 m guard columns used in this application are segments of a 20 m x 0.18 mm ID x 0.18 µm df Rxi-5ms column (cat.# 13402). The 20 m column was cut to yield one 10 m analytical column and five 2 m guard columns.
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.