Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH
This chromatogram may contain analytes that are synonyms of your search terms.

Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH

PeaksConc.
(µg/mL)
1.Naphthalene-d82.0
2.Naphthalene0.62
3.2-Methylnaphthalene0.13
4.Biphenyl0.24
5.Acenaphthylene0.40
6.Acenaphthene-d102.0
7.Acenaphthene0.37
8.Fluorene0.33
9.Dibenzothiophene0.19
10.Phenanthrene-d102.0
11.Phenanthrene0.63
12.Anthracene0.29
13.4H-Cyclopenta[def]phenanthrene0.10
14.Fluoranthene0.49
15.Pyrene0.51
16.Benzo[c]fluorene0.13
17.Benzo[ghi]fluoranthene0.15
18.Benzo[c]phenanthrene0.20
19.Benz[a]anthracene0.32
20.Chrysene-D122.0
21.Cyclopenta[cd]pyrene0.21
22.Triphenylene0.18
23.Chrysene0.33
24.5-Methylchrysene0.13
PeaksConc.
(µg/mL)
25.Benzo[b]fluoranthene0.47
26.Benzo[k]fluoranthene0.27
27.Benzo[j]fluoranthene0.30
28.Benzo[a]fluoranthene0.10
29.Benzo[e]pyrene0.32
30.Benzo[a]pyrene-d122.0
31.Benzo[a]pyrene0.33
32.Perylene-d122.0
33.Perylene0.32
34.Dibenzo[a,j]anthracene0.20
35.Dibenzo[a,c]anthracene0.13
36.Indeno[1,2,3-cd]pyrene0.32
37.Dibenz[a,h]anthracene0.32
38.Benzo[b]chrysene0.18
39.Picene0.14
40.Benzo[ghi]perylene0.37
41.Anthanthrene0.10
42.Dibenzo[b,k]fluoranthene0.070
43.Dibenzo[a,l]pyrene0.13
44.Dibenzo[a,e]pyrene0.22
45.Coronene-d122.0
46.Coronene0.10
47.Dibenzo[a,i]pyrene0.13
48.Dibenzo[a,h]pyrene0.13
image
GC_EV1394
ColumnRxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
SampleSV internal standard mix (cat.# 31206)
Coronene-d12 (CIL DLM-2715)
Benzo[a]pyrene-d12 (CIL DLM-258-0)
Aromatics in toluene (NIST SRM-2260a)
PAH native stock solution (Wellington PAH-STK-B)
Diluent:Dichloromethane
Injection
Inj. Vol.:1 µL split (split ratio 10:1)
Liner:Premium 4 mm Precision liner w/wool (cat.# 23305.1)
Inj. Temp.:275 °C
Split Vent Flow Rate:19.5 mL/min
Oven
Oven Temp.:110 °C (hold 1.6 min) to 210 °C at 24 °C/min to 295 °C at 1.9 °C/min to 350 °C at 3.7 °C/min (hold 6 min)
Carrier GasHe, constant flow
Flow Rate:1.95 mL/min
DetectorMS
Mode:SIM
SIM Program:
GroupStart Time
(min)
Ion(s) (m/z)Dwell (ms)
13.09102.1, 108.1, 128.1, 136.2 40
25.69115.1, 142.1 40
36.2376.1, 141.1, 154.1, 156.2 40
46.9575.6, 76.1, 91.1, 152.1, 153.1, 155.1, 162.2, 170.2 20
57.9382.4, 165.1 40
69.19139.1, 152.1, 160.2, 178.1, 184.1, 188.2 40
711.7894.6, 165.1, 190.1, 192.1 40
814.19101.1, 202.1 40
916.60101.1, 202.1 40
1018.4992.1, 184.1 40
1119.58108, 216 40
1222.3196.1, 212.2 40
1324.92113.1, 226.1, 228.1 40
1426.27113.1, 114.0, 120.1, 226.1, 228.1, 240.1 40
1528.75154.1, 252.1 35
1630.62119.8, 242.2 40
1735.29126.1, 252.1 40
1838.56125.1, 252.1 40
1939.23126.1, 252.1 40
2040.71125.1, 126.1, 132.1, 252.1, 264.1 40
2142.91125, 132.2, 252.1, 264.1 40
2244.35252.1, 268.1 40
2348.41139.1, 139.5, 278.1, 279.1 40
2452.13139.1, 139.5, 278.1, 279.1 40
2553.70138.1, 139.1, 278.1 40
2654.97138.1, 276.1 40
2755.92138.1, 276.1 40
2857.04132.6, 267.1 40
2959.69151.0, 302.1 40
3063.27150, 151, 156.1, 300.1, 302.1, 312.1 40
3164.78151.0, 302.1 40
Transfer Line Temp.:330 °C
Analyzer Type:Quadrupole
Source Type:Extractor
Extractor Lens:9 mm ID
Source Temp.:350 °C
Quad Temp.:200 °C
Solvent Delay Time:3 min
Tune Type:DFTPP
Ionization Mode:EI
InstrumentAgilent 7890B GC & 5977A MSD
NotesPerforms the separation of two critical sets of isobars:
1. Cyclopenta[c,d]pyrene, triphenylene, and chrysene
2. Benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[j]fluoranthene
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

benzofluoranthenes

,

benzo[j]fluoranthene

,

chrysene

,

triphenylene

,

isobaric

,

isobar

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us