delim
delim
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH (30 m x 0.25 mm ID x 0.10 µm df )
This chromatogram may contain analytes that are synonyms of your search terms.

Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH (30 m x 0.25 mm ID x 0.10 µm df )

PeaksConc.
(µg/mL)
1.Naphthalene1.0
2.2-Methylnaphthalene0.80
3.1-Methylnaphthalene0.80
4.2,6-Dimethylnaphthalene0.80
5.Acenaphthylene1.0
6.Acenaphthene-d1020
7.Acenaphthene1.0
8.2,3,5-Trimethylnaphthalene0.80
9.Fluorene1.0
10.Dibenzothiophene0.80
11.Phenanthrene-d1020
12.Phenanthrene1.0
13.Anthracene1.0
14.1-Methylphenanthrene0.80
15.Fluoranthene1.0
16.Pyrene1.0
17.Benzidine1.0
18.3,3'-Dimethylbenzidine1.0
19.Benz[a]anthracene1.0
20.Chrysene-d1220
PeaksConc.
(µg/mL)
21.Cyclopenta[cd]pyrene0.20
22.Triphenylene1.0
23.Chrysene1.0
24.3,3'-Dichlorobenzidine1.0
25.5-Methylchrysene0.20
26.Benzo[b]fluoranthene1.0
27.Benzo[k]fluoranthene1.0
28.Benzo[j]fluoranthene1.0
29.Benzo[a]pyrene-d121.0
30.Benzo[a]pyrene1.0
31.3-Methylcholanthrene0.80
32.Dibenz(a,h)acridine0.80
33.Dibenz[a,j]acridine0.80
34.Indeno[1,2,3-cd]pyrene1.0
35.Dibenz[a,h]anthracene1.0
36.Benzo[ghi]perylene1.0
37.7H-Dibenzo[c,g]carbazole0.80
38.Dibenzo[a,l]pyrene0.20
39.Dibenzo[a,e]pyrene1.0
40.Dibenzo[a,i]pyrene1.0
41.Dibenzo[a,h]pyrene1.0
0.010 to 1.0 ng on column
image
GC_EV1397
ColumnRxi-PAH, 30 m, 0.25 mm ID, 0.10 µm (cat.# 49318)
SampleMethod 525.2 internal standard mix (cat.# 31825)
Triphenylene (CS S-13711U1)
Benzo[a]pyrene-d12 (CIL DLM-258-0)
Custom PAH SIM spike mix (cat.# 557484)
PAH native stock solution (Wellington PAH-STK-A)
PAH supplement mix for Method 8100 (cat.# 31857)
Diluent:Dichloromethane
Injection
Inj. Vol.:0.5 µL split (split ratio 10:1)
Liner:2 mm Precision liner w/deactivated wool (cat.# 20823)
Inj. Temp.:275 °C
Oven
Oven Temp.:110 °C (hold 0.57 min) to 175 °C at 65 °C/min to 210 °C at 45 °C/min to 295 °C at 5.3 °C/min to 350 °C at 35 °C/min (hold 5 min)
Carrier GasHe, constant flow
Flow Rate:2 mL/min
DetectorMS
Mode:SIM
SIM Program:
GroupStart Time
(min)
Ion(s) (m/z)Dwell (ms)
11.05102, 128 25
22.08115, 141, 142, 156 25
32.5875.9, 80, 82.3, 152, 153, 154, 155, 162, 165, 170 15
43.4989, 94, 139, 152, 160, 178, 183, 188 15
54.4194.5, 165, 192 25
65.35100.9, 202 25
76.8792, 184 25
88.29106, 212 25
99.63113, 114, 120.1, 226, 228, 240.1 25
1010.57154, 251.9 25
1111.40119.7, 242 25
1213.16124.9, 126, 252 25
1314.96112.8, 118, 125.9, 132, 252, 264 25
1416.09126.1, 252, 268 25
1517.82138, 138.9, 139.2, 276, 278, 279 25
1619.57137.9, 267, 276 25
1720.77150, 302 25
1821.57149.9, 151, 302 25
Transfer Line Temp.:330 °C
Analyzer Type:Quadrupole
Source Type:Extractor
Extractor Lens:9 mm ID
Source Temp.:350 °C
Quad Temp.:200 °C
Solvent Delay Time:1.05 min
Tune Type:DFTPP
Ionization Mode:EI
InstrumentAgilent 7890B GC & 5977A MSD
NotesPerforms the separation of two critical sets of isobars:
1. Cyclopenta[c,d]pyrene, triphenylene, and chrysene
2. Benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[j]fluoranthene
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

benzo[j]fluoranthene

,

chrysene

,

triphenylene

,

isobaric

,

isobar

,

benzofluoranthenes

,

sediment

,

environmental forensics

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us