PCB Congener Mix (EPA Method 8082A) on the Rtx-PCB Column
This chromatogram may contain analytes that are synonyms of your search terms.

PCB Congener Mix (EPA Method 8082A) on the Rtx-PCB Column

Peaks
1.2-Chlorobiphenyl (PCB-1)
2.2,3-Dichlorobiphenyl (PCB-5)
3.2,2′,5-Trichlorobiphenyl (PCB-18)
4.2,4′,5-Trichlorobiphenyl (PCB-31)
5. 2,2′,5,5′-Tetrachlorobiphenyl (PCB-52)
6.2,2′,3,5′-Tetrachlorobiphenyl (PCB-44)
7.2,3′,4,4′-Tetrachlorobiphenyl (PCB-66)
8.2,2′,4,5,5′-Pentachlorobiphenyl (PCB-101)
9.2,2′,3,4,5′-Pentachlorobiphenyl (PCB-87)
Peaks
10.2,3,3′,4′,6-Pentachlorobiphenyl (PCB-110)
11.2,2′,3,5,5′,6-Hexachlorobiphenyl (PCB-151)
12.2,2′,4,4′,5,5′-Hexachlorobiphenyl (PCB-153)
13.2,2′,3,4,5,5′-Hexachlorobiphenyl (PCB-141)
14.2,2′,3,4,4′,5′-Hexachlorobiphenyl (PCB-138)
15.2,2′,3,4′,5,5′,6-Heptachlorobiphenyl (PCB-187)
16.2,2′,3,4,4′,5′,6-Heptachlorobiphenyl (PCB-183)
17.2,2′,3,4,4′,5,5′-Heptachlorobiphenyl (PCB-180)
18.2,2′,3,3′,4,4′,5-Heptachlorobiphenyl (PCB-170)
19.2,2′,3,3′,4,4′,5,5′,6-Nonachlorobiphenyl (PCB-206)
image
GC_EV1398
ColumnRtx-PCB, 20 m, 0.18 mm ID, 0.18 µm (cat.# 41302)
SamplePCB congener mix, Method 8082A (cat.# 32416)
Diluent:Isooctane
Conc.:50 µg/mL
Injection
Inj. Vol.:1 µL split (split ratio 10:1)
Liner:Premium 4 mm Precision liner w/wool (cat.# 23305.5)
Inj. Temp.:250 °C
Oven
Oven Temp.:120 °C (hold 0.1 min) to 330 °C at 6.8 °C/min (hold 1 min)
Carrier GasHe, constant flow
Flow Rate:1 mL/min
DetectorMS-scan (positive ion chemical ionization emulating EI [EI-CI source.u])
Scan Program:
GroupStart Time
(min)
Scan Range
(amu)
Scan Rate
(scans/sec)
1350-5505.6
Transfer Line Temp.:280 °C
Analyzer Type:Quadrupole
Source Type:CI
Source Temp.:300 °C
Quad Temp.:200 °C
Ionization Mode:CI(pos)
InstrumentAgilent 7890B GC & 5977A MSD
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

PCB

,

,

Polychlorinated Biphenyls

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us