share:
delim
delim
Semivolatiles on Rxi-5ms (Split Injection)
This chromatogram may contain analytes that are synonyms of your search terms.

Semivolatiles on Rxi-5ms (Split Injection)

PeakstR (min)
1.1,4-Dioxane-D8 (IS) 1.98
2.N-Nitrosodimethylamine2.15
3.Pyridine2.18
4.2-Fluorophenol (SS) 2.87
5.Phenol-D6 (SS) 3.48
6.Phenol3.49
7.Aniline3.54
8.bis-(2-chloroethyl)ether3.57
9.2-Chlorophenol3.62
10.1,3-Dichlorobenzene3.74
11.1,4-Dichlorobenzene-D4 (IS) 3.76
12.1,4-Dichlorobenzene3.77
13.Benzyl Alcohol3.86
14.1,2-Dichlorobenzene3.92
15.2-Methylphenol3.95
16.Bis(2-Chloroisopropyl)ether3.98
17.4-Methylphenol4.06
18.3-Methylphenol4.06
19.N-Nitrosodi-N-propylamine4.09
20.Hexachloroethane4.17
21.Nitrobenzene-D5 (SS) 4.21
22.Nitrobenzene4.22
23.Isophorone4.41
24.2-Nitrophenol4.49
25.2,4-Dimethylphenol4.5
26.Benzoic acid4.54
27.Bis(2-chloroethoxy)methane4.58
28.2,4-Dichlorophenol4.67
29.1,2,4-Trichlorobenzene4.76
30.Naphthalene-D8 (IS) 4.79
31.Naphthalene4.81
32.4-Chloroaniline4.86
33.Hexachlorobutadiene4.96
34.4-Chloro-3-methylphenol5.26
35.2-Methylnaphthalene5.4
36.1-Methylnaphthalene5.49
37.Hexachlorocyclopentadiene5.6
38.2,4,6-Trichlorophenol5.66
39.2,4,5-Trichlorophenol5.69
40.2-Fluorobiphenyl (SS) 5.73
41.2-Chloronaphthalene5.82
42.2-Nitroaniline5.93
43.1,4-Dinitrobenzene6.02
44.Dimethyl phthalate6.11
45.1,3-Dinitrobenzene6.12
46.2,6-Dinitrotoluene6.17
47.Acenaphthylene6.19
PeakstR (min)
48.1,2-Dinitrobenzene6.23
49.3-Nitroaniline6.29
50.Acenaphthene-D10 (IS) 6.33
51.Acenaphthene6.35
52.2,4-Dinitrophenol6.38
53.4-Nitrophenol6.42
54.Dibenzofuran6.49
55.2,4-Dinitrotoluene6.51
56.2,3,5,6-Tetrachlorophenol6.59
57.2,3,4,6-Tetrachlorophenol6.63
58.Diethyl Phthalate6.72
59.4-Chlorophenyl phenyl ether6.79
60.Fluorene6.8
61.4-Nitroaniline6.83
62.4,6-Dinitro-2-methylphenol6.87
63.N-Nitrosodiphenylamine (as Diphenylamine)6.89
64.N,N'-Diphenylhydrazine (as Azobenzene)6.93
65.2,4,6-Tribromophenol (SS) 7.02
66.4-Bromophenyl phenyl ether7.22
67.Hexachlorobenzene7.36
68.Pentachlorophenol7.51
69.Phenanthrene-D10 (IS) 7.62
70.Phenanthrene7.64
71.Anthracene7.68
72.Carbazole7.82
73.di-n-Butyl phthalate8.16
74.Fluoranthene8.73
75.Benzidine8.85
76.Pyrene-D10 (SS) 8.95
77.Pyrene8.97
78.p-Terphenyl-D14 (SS) 9.14
79.3,3'-Dimethylbenzidine9.74
80.Butyl benzyl phthalate9.79
81.Bis(2-ethylhexyl) adipate9.89
82.3,3'-Dichlorobenzidine10.6
83.Benz[a]anthracene10.62
84.Chrysene-D12 (IS) 10.65
85.Chrysene10.69
86.Bis(2-ethylhexyl) phthalate10.8
87.Di-n-octyl phthalate12.14
88.Benzo[b]fluoranthene12.93
89.Benzo[k]fluoranthene12.99
90.Benzo[a]pyrene13.77
91.Perylene-D12 (IS) 13.93
92.Indeno[1,2,3-cd]pyrene16.56
93.Dibenz[a,h]anthracene16.62
94.Benzo[ghi]perylene17
image
GC_EV1418
ColumnRxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
SampleRevised SV internal standard mix (cat.# 31886)
Revised B/N surrogate mix (cat.# 31888)
Acid surrogate mix (4/89 SOW) (cat.# 31063)
8270 MegaMix (cat.# 31850)
8270 Benzidines mix (cat.# 31852)
Benzoic acid (cat.# 31879)
Diluent:Dichloromethane
Conc.:5.0 ng/µL (IS and SS concentrations are 20 ng/µL)
Injection
Inj. Vol.:1 µL split (split ratio 10:1)
Liner:Premium 4 mm Precision liner w/wool (cat.# 23305.5)
Inj. Temp.:275 °C
Oven
Oven Temp.:50 °C (hold 0.5 min) to 265 °C at 28 °C/min to 285 °C at 3 °C/min to 330 °C at 20 °C/min (hold 5 min)
Carrier GasHe, constant flow
Flow Rate:1.44 mL/min
DetectorMS
Mode:Scan
Scan Program:
GroupStart Time
(min)
Scan Range
(amu)
Scan Rate
(scans/sec)
11.535-5505.4
Transfer Line Temp.:280 °C
Analyzer Type:Quadrupole
Source Type:Extractor
Extractor Lens:9mm ID
Source Temp.:350 °C
Quad Temp.:200 °C
Electron Energy:70 eV
Tune Type:DFTPP
Ionization Mode:EI
InstrumentAgilent 7890B GC & 5977A MSD
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

EPA Method 8270

,

EPA Method 625

,

EPA Method TO-17

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us