share:
delim
delim
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven

PeakstR (min)
1.1,4-Dioxane-d8 (IS)1.32
2.N-Nitrosodimethylamine1.43
3.Pyridine1.45
4.2-Fluorophenol (SS)1.87
5.Phenol-d6 (SS)2.20
6.Phenol2.20
7.Aniline2.23
8.Bis(2-chloroethyl) ether2.24
9.2-Chlorophenol2.28
10.1,3-Dichlorobenzene2.34
11.1,4-Dichlorobenzene-d4 (IS)2.35
12.1,4-Dichlorobenzene2.36
13.Benzyl alcohol2.40
14.1,2-Dichlorobenzene2.42
15.2-Methylphenol2.44
16.Bis(2-chloroisopropyl)ether2.45
17.4-Methylphenol2.50
18.3-Methylphenol2.50
19.N-Nitrosodi-N-propylamine2.50
20.Hexachloroethane2.56
21.Nitrobenzene-d5 (SS)2.57
22.Nitrobenzene2.58
23.Isophorone2.67
24.2-Nitrophenol2.71
25.2,4-Dimethylphenol2.71
26.Benzoic acid2.74
27.Bis(2-chloroethoxy)methane2.75
28.2,4-Dichlorophenol2.80
29.1,2,4-Trichlorobenzene2.84
30.Naphthalene-D8 (IS)2.87
31.Naphthalene2.88
32.4-Chloroaniline2.89
33.Hexachlorobutadiene2.93
34.4-Chloro-3-methylphenol3.09
35.2-Methylnaphthalene3.17
36.1-Methylnaphthalene3.21
37.Hexachlorocyclopentadiene3.23
38.2,4,6-Trichlorophenol3.28
39.2,4,5-Trichlorophenol3.30
40.2-Fluorobiphenyl (SS)3.32
41.2-Chloronaphthalene3.38
42.2-Nitroaniline3.41
43.1,4-Dinitrobenzene3.46
44.Dimethyl phthalate3.49
45.1,3-Dinitrobenzene3.50
46.2,6-Dinitrotoluene3.51
47.1,2-Dinitrobenzene3.54
PeakstR (min)
48.Acenaphthylene3.56
49.3-Nitroaniline3.59
50.Acenaphthene-d10 (IS)3.62
51.Acenaphthene3.63
52.2,4-Dinitrophenol3.63
53.4-Nitrophenol3.65
54.2,4-Dinitrotoluene3.69
55.Dibenzofuran3.70
56.2,3,5,6-Tetrachlorophenol3.73
57.2,3,4,6-Tetrachlorophenol3.75
58.Diethyl Phthalate3.79
59.4-Chlorophenyl phenyl ether3.84
60.Fluorene3.85
61.4-Nitroaniline3.85
62.4,6-Dinitro-2-methylphenol3.86
63.N-Nitrosodiphenylamine (as diphenylamine)3.89
64.N-N-Diphenylhydrazine (as azobenzene)3.91
65.2,4,6-Tribromophenol (SS)3.95
66.4-Bromophenyl phenyl ether4.06
67.Hexachlorobenzene4.09
68.Pentachlorophenol4.17
69.Phenanthrene-d10 (IS)4.26
70.Phenanthrene4.27
71.Anthracene4.29
72.Carbazole4.36
73.di-n-Butyl phthalate4.49
74.Fluoranthene4.79
75.Pyrene4.79
76.Benzidine4.84
77.Pyrene-d10 (IS)4.89
78.p-Terphenyl-d14 (SS)4.96
79.Butyl benzyl phthalate5.19
80.3,3'-Dimethylbenzidine5.20
81.Bis(2-ethylhexyl) adipate5.22
82.3,3'-Dichlorobenzidine5.52
83.Bis(2-ethylhexyl) phthalate5.53
84.Benz[a]anthracene5.55
85.Chrysene-d12 (IS)5.56
86.Chrysene5.58
87.Di-n-octyl phthalate6.02
88.Benzo[b]fluoranthene6.40
89.Benzo[k]fluoranthene6.42
90.Benzo[a]pyrene6.71
91.Perylene-d12 (IS)6.77
92.Indeno[1,2,3-cd]pyrene7.98
93.Dibenz[a,h]anthracene8.01
94.Benzo[ghi]perylene8.30
image
GC_EV1475
ColumnRxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Sample8270 MegaMix (cat.# 31850)
8270 Benzidines mix (cat.# 31852)
Benzoic acid (cat.# 31879)
Revised B/N surrogate mix (cat.# 31888)
Acid surrogate mix (4/89 SOW) (cat.# 31063)
Revised SV internal standard mix (cat.# 31886)
Diluent:Methylene chloride
Conc.:20 µg/mL (IS/SS 20 µg/mL)
Injection
Inj. Vol.:1 µL split (split ratio 20:1)
Liner:Topaz 4 mm single taper w/wool (cat.# 23303)
Inj. Temp.:275 °C
Oven
Oven Temp.:45 °C (hold 0.5 min) to 285 °C at 56.5 °C/min to 305 °C at 6 °C/min to 330 °C at 60.5 °C/min (hold 2.5 min)
Carrier GasHe, constant flow
Flow Rate:1.0 mL/min
DetectorMS
Mode:Scan
Transfer Line Temp.:280 °C
Analyzer Type:Quadrupole
Source Temp.:330 °C
Quad Temp.:180 °C
Electron Energy:70 eV
Solvent Delay Time:1.3 min
Tune Type:DFTPP
Ionization Mode:EI
Scan Range:39-550 amu
Scan Rate:9.8 scans/sec
InstrumentAgilent 7890B GC & 5977A MSD
NotesAnalyzed using a 208 V oven equipped with the GC Accelerator kit (cat.# 23849).
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

split

,

injection

,

8270

,

EPA

,

8270D

,

SVOA

,

semivolatiles

,

SVOC

,

wool

,

Precision

,

Liner

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us