This site requires that Javascript be enabled. Please enable Javascript in your browser.
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
This chromatogram may contain analytes that are synonyms of your search terms.
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Peaks tR (min)
1. 1,4-Dioxane-d8 (IS) 1.32
2. N-Nitrosodimethylamine 1.43
3. Pyridine 1.45
4. 2-Fluorophenol (SS) 1.87
5. Phenol-d6 (SS) 2.20
6. Phenol 2.20
7. Aniline 2.23
8. Bis(2-chloroethyl) ether 2.24
9. 2-Chlorophenol 2.28
10. 1,3-Dichlorobenzene 2.34
11. 1,4-Dichlorobenzene-d4 (IS) 2.35
12. 1,4-Dichlorobenzene 2.36
13. Benzyl alcohol 2.40
14. 1,2-Dichlorobenzene 2.42
15. 2-Methylphenol 2.44
16. Bis(2-chloroisopropyl)ether 2.45
17. 4-Methylphenol 2.50
18. 3-Methylphenol 2.50
19. N-Nitrosodi-N-propylamine 2.50
20. Hexachloroethane 2.56
21. Nitrobenzene-d5 (SS) 2.57
22. Nitrobenzene 2.58
23. Isophorone 2.67
24. 2-Nitrophenol 2.71
25. 2,4-Dimethylphenol 2.71
26. Benzoic acid 2.74
27. Bis(2-chloroethoxy)methane 2.75
28. 2,4-Dichlorophenol 2.80
29. 1,2,4-Trichlorobenzene 2.84
30. Naphthalene-D8 (IS) 2.87
31. Naphthalene 2.88
32. 4-Chloroaniline 2.89
33. Hexachlorobutadiene 2.93
34. 4-Chloro-3-methylphenol 3.09
35. 2-Methylnaphthalene 3.17
36. 1-Methylnaphthalene 3.21
37. Hexachlorocyclopentadiene 3.23
38. 2,4,6-Trichlorophenol 3.28
39. 2,4,5-Trichlorophenol 3.30
40. 2-Fluorobiphenyl (SS) 3.32
41. 2-Chloronaphthalene 3.38
42. 2-Nitroaniline 3.41
43. 1,4-Dinitrobenzene 3.46
44. Dimethyl phthalate 3.49
45. 1,3-Dinitrobenzene 3.50
46. 2,6-Dinitrotoluene 3.51
47. 1,2-Dinitrobenzene 3.54
Peaks tR (min)
48. Acenaphthylene 3.56
49. 3-Nitroaniline 3.59
50. Acenaphthene-d10 (IS) 3.62
51. Acenaphthene 3.63
52. 2,4-Dinitrophenol 3.63
53. 4-Nitrophenol 3.65
54. 2,4-Dinitrotoluene 3.69
55. Dibenzofuran 3.70
56. 2,3,5,6-Tetrachlorophenol 3.73
57. 2,3,4,6-Tetrachlorophenol 3.75
58. Diethyl Phthalate 3.79
59. 4-Chlorophenyl phenyl ether 3.84
60. Fluorene 3.85
61. 4-Nitroaniline 3.85
62. 4,6-Dinitro-2-methylphenol 3.86
63. N-Nitrosodiphenylamine (as diphenylamine) 3.89
64. N-N-Diphenylhydrazine (as azobenzene) 3.91
65. 2,4,6-Tribromophenol (SS) 3.95
66. 4-Bromophenyl phenyl ether 4.06
67. Hexachlorobenzene 4.09
68. Pentachlorophenol 4.17
69. Phenanthrene-d10 (IS) 4.26
70. Phenanthrene 4.27
71. Anthracene 4.29
72. Carbazole 4.36
73. di-n- Butyl phthalate 4.49
74. Fluoranthene 4.79
75. Pyrene 4.79
76. Benzidine 4.84
77. Pyrene-d10 (IS) 4.89
78. p- Terphenyl-d14 (SS)4.96
79. Butyl benzyl phthalate 5.19
80. 3,3'-Dimethylbenzidine 5.20
81. Bis(2-ethylhexyl) adipate 5.22
82. 3,3'-Dichlorobenzidine 5.52
83. Bis(2-ethylhexyl) phthalate 5.53
84. Benz[a]anthracene 5.55
85. Chrysene-d12 (IS) 5.56
86. Chrysene 5.58
87. Di-n- octyl phthalate 6.02
88. Benzo[b]fluoranthene 6.40
89. Benzo[k]fluoranthene 6.42
90. Benzo[a]pyrene 6.71
91. Perylene-d12 (IS) 6.77
92. Indeno[1,2,3-cd]pyrene 7.98
93. Dibenz[a,h]anthracene 8.01
94. Benzo[ghi]perylene 8.30
GC_EV1475
Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816) 8270 MegaMix (cat.# 31850) 8270 Benzidines mix (cat.# 31852) Benzoic acid (cat.# 31879) Revised B/N surrogate mix (cat.# 31888) Acid surrogate mix (4/89 SOW) (cat.# 31063) Revised SV internal standard mix (cat.# 31886)
Methylene chloride 20 µg/mL (IS/SS 20 µg/mL) 1 µL split (split ratio 20:1) Topaz 4 mm single taper w/wool (cat.# 23303) 275 °C 45 °C (hold 0.5 min) to 285 °C at 56.5 °C/min to 305 °C at 6 °C/min to 330 °C at 60.5 °C/min (hold 2.5 min) He, constant flow 1.0 mL/min MS Scan 280 °C Quadrupole 330 °C 180 °C 70 eV 1.3 min DFTPP EI 39-550 amu 9.8 scans/sec Agilent 7890B GC & 5977A MSD Analyzed using a 208 V oven equipped with the GC Accelerator kit (cat.# 23849).
Download PDF RELATED CHROMATOGRAM LIBRARY SEARCHES
,
,
,
,
,
,
,
,
,
,
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy .