share:
delim
delim
Malt Whiskey on Stabilwax-DA
This chromatogram may contain analytes that are synonyms of your search terms.

Malt Whiskey on Stabilwax-DA

Peaks
1.Ethyl octanoate
2.Acetic acid
3.Siloxane
4.1-Hydroxy-2,3-butadione
5.1-Hydroxy-2-propanone acetate
6.Furfural
7.Formic acid
8.Propionic acid
9.Isobutyric acid
10.Dimethyl Sulfoxide
11.5-Methyl furfural
12.Methyl decanoate + unknown
13.Butyric acid
14.Siloxane
15.Ethyl decanoate
16.Furfuryl alcohol
17.Isoamyl octanoate
18.Isovaleric acid
19.2-Methylbutyric acid
20.Diethyl succinate
21.3-Methyl-2(5H)-furanone (possible)
22.Valeric acid
23.Ethyl undecanoate
24.Isobutyl decanoate
25.2(5H)-Furanone
26.Unknown
27.Diethylene glycol butyl ether
28.Siloxane
29.Methyl dodecanoate
30.2-Phenylethyl acetate
31.Methylcyclopentenolone
32.Hexanoic acid
33.Ethyl dodecanoate
34.Isoamyl decanoate
35.Guaiacol
36.Dodecyl acetate (possible)
37.Whiskey lactone (1)
38.2-Phenylethanol
39.Heptanoic acid
40.Siloxane
41.Dimethoxybenzene or 4-Methylguaiacol
42.Whiskey lactone (2)
43.Dodecanol
44.Unknown
45.Phenol
46.Methyl tetradecanoate
47.Nerolidol
48.Diethyl malate
Peaks
49.Ethyl tetradecanoate
50.Octanoic Acid
51.Unknown
52.p-Cresol
53.Siloxane
54.Diethyl octanedioate
55.Monomethyl succinate (possible)
56.3,5-Dimethyl-2,4(5H)furandione
57.Nonanoic acid
58.Diethyl 2-hydroxyglutarate
59.Unknown
60.Tetradecanol
61.4-Vinylguaiacol
62.Diethyl nonanedioate
63.Methyl hexadecanoate
64.Ethyl γ-lactone 2-hydroxyglutarate
65.Ethyl hexadecanoate
66.Decanoic acid
67.Ethyl 9-hexadecanoate
68.Triacosan
69.Unknown
70.Phthalide
71.Diethyl Phthalate
72.Hexadecanol
73.4-Hydroxycinnamic acid (decomp.)
74.Methyl stearate
75.Benzoic acid
76.Methyl 8-octadecenoate
77.Ethyl stearate
78.Dodecanoic acid
79.Hydroxymethylfurfural
80.Ethyl linoleate
81.4-Allyl-2,6-dimethoxyphenol
82.Diisobutyl phthalate
83.Vanillin
84.Sinapic acid (decomp.)
85.2-Phenylethyl decanoate +2 unknowns
86.4-Propenyl-2,6-dimethoxyphenol
87.Ethyl vanillate
88.Acetovanillone
89.Vanillin methyl ketone
90.Tetradecanoic acid
91.Ethyl homovanillate
92.propiovanillone
93.fatty acid ester
94.similar to 4-Allyl-2,6-dimethoxyphenol
95.Unknown
96.Hexadecanoic acid
97.Syringaldehyde
image
GC_FF00603
ColumnStabilwax-DA, 30 m, 0.18 mm ID, 0.18 µm
Samplemalt whiskey
Conc.: neat
Injection
Inj. Vol.:10 µL PTV splitless
Inlet Temp. Program:35 °C (hold 2 min) to 300 °C at 10 °C/min (hold 5 min)
Oven
Oven Temp.:60 °C (hold 2 min) to 100 °C at 20 °C/min to 240 °C at 5 °C/min (hold 10 min)
Carrier GasHe, constant linear velocity
Linear Velocity:45 cm/sec
DetectorMS
Mode:Scan
Transfer Line Temp.:240 °C
Analyzer Type:Quadrupole
Source Temp.:230 °C
Quad Temp.:150 °C
Electron Energy:70 eV
Ionization Mode:EI
Scan Range:30-400 amu
NotesInjection: 10 µL large volume at 10 µL/min.
Helium vent flow: 600 mL/min. with 1.8 min. vent end time
AcknowledgementChromatogram courtesy of Kevin MacNamara, Ph.D., Irish Distilleries, Ltd.
Download PDF

RELATED CHROMATOGRAM LIBRARY SEARCHES

Malt

,

Whiskey

,

Stabilwax®-DA

,

flavors

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us