Food Industry FAME on FAMEWAX by EN14103 (2011)
Peaks
tR (min)
Conc. (mg/mL)
Structural Nomenclature
1.
Methyl capronate
3.629
1.2
C6:0
2.
Methyl caprylate
6.237
1.2
C8:0
3.
Methyl caprate
8.787
1.2
C10:0
4.
Methyl undecanoate
9.971
0.6
C11:0
5.
Methyl laurate
11.105
1.2
C12:0
6.
Methyl tridecanoate
12.179
0.6
C13:0
7.
Methyl myristate
13.215
1.2
C14:0
8.
Methyl myristoleate
13.549
0.6
C14:1 (cis-9)
9.
Methyl pentadecanoate
14.196
0.6
C15:0
10.
Methyl pentadecenoate
14.524
0.6
C15:1 (cis-10)
11.
Methyl palmitate
15.152
1.8
C16:0
12.
Methyl palmitoleate
15.355
0.6
C16:1 (cis-9)
13.
Methyl margarate
16.052
0.6
C17:0
14.
Methyl heptadecenoate
16.261
0.6
C17:1 (cis-10)
15.
Methyl stearate
16.995
1.2
C18:0
16.
Methyl oleate
17.156
1.2
C18:1 (cis-9)
17.
Methyl elaidate
17.168
1.2
C18:1 (trans-9)
18.
Methyl linoleate
17.583
0.6
C18:2 (all-cis-9,12)
19.
Methyl linolelaidate
17.641
0.6
C18:2 (all-trans-9,12)
20.
Methyl γ-linolenate
17.874
0.6
C18:3 (all-cis-6,9,12)
21.
Methyl nonadecanoate
18.052
2.0
C19:0
22.
Methyl α-linolenate
18.223
0.6
C18:3 (all-cis-9,12,15)
23.
Methyl arachidate
19.075
1.2
C20:0
24.
Methyl (Z)-11-eicosenoate
19.255
0.6
C20:1 (cis-11)
25.
Methyl 11,14-eicosadienoate
19.761
0.6
C20:2 (all-cis-11,14)
26.
Methyl eicosa-8,11,14-trienoate
20.046
0.6
C20:3 (all-cis-8,11,14)
27.
Methyl heneicosanoate
20.197
0.6
C21:0
28.
Methyl arachidonate
20.290
0.6
C20:4 (all-cis-5,8,11,14)
29.
Methyl 11,14,17-eicosatrienoate
20.488
0.6
C20:3 (all-cis-11,14,17)
30.
Methyl 5,8,11,14,17-eicosapentanoate
21.036
0.6
C20:5 (all-cis-5,8,11,14,17)
31.
Methyl behenate
21.39
1.2
C22:0
32.
Methyl erucate
21.595
0.6
C22:1 (cis-13)
33.
Methyl docosadienoate
22.150
0.6
C22:2 (all-cis-13,16)
34.
Methyl tricosanoate
22.584
0.6
C23:0
35.
Methyl lignocerate
23.826
1.2
C24:0
36.
Methyl docosahexaenoate
23.863
0.6
C22:6 (all-cis-4,7,10,13,16,19)
37.
Methyl nervonate
24.055
0.6
C24:1 (cis-15)
GC_PC1332
Column
FAMEWAX, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12497)
Sample
Food industry FAME mix (cat.# 35077)
Methyl nonadecanoate (cat.# 35055)
Diluent:
Standard cat.# 35055 was dissolved in toluene.
Injection
Inj. Vol.:
1 µL split (split ratio 100:1)
Liner:
Topaz 4.0 mm ID Precision inlet liner w/wool (cat.# 23305)
Inj. Temp.:
240 °C
Oven
Oven Temp.:
60 °C (hold 2 min) to 200 °C at 10 °C/min to 240 °C at 5 °C/min (hold 7 min)
Carrier Gas
H2, constant flow
Flow Rate:
1.7 mL/min
Detector
FID @ 250 °C
Instrument
Agilent 7890B GC
Notes
This chromatogram is an overlay of two injections: food industry FAME standard (black) and C19:0 methyl ester in toluene (red). An excellent separation of C19:0 (used in EN 14103 as an internal standard) and the most prevalent FAMEs found in biodiesel blends was achieved. Note that C4:0 from the food industry FAME standard elutes in the solvent front.
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Recommendations
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy.
Restek Domestic Customer Service
Thank you
Your message has been sent. We will be in touch shortly.
Message not sent
Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.