share:
delim
delim
Sugars: Maple Flavored Syrup on Ultra Amino

Sugars: Maple Flavored Syrup on Ultra Amino

Peaks
1.Fructose
2.Glucose
3.Sucrose
image
LC_0159
ColumnUltra Amino (cat.# 9107365)
Dimensions:150 mm x 4.6 mm ID
Particle Size:3 µm
Pore Size:100 Å
Temp.:35 °C
Sample10% Solution of maple syrup
Diluent:Acetonitrile:water (70:30, v/v)
Inj. Vol.:20 µL
Mobile PhaseWater:acetonitrile (25:75)
Flow:0.8 mL/min
DetectorRI
Cell Temp:35 °C
Download PDF

Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us