California Cannabis Pesticides and Mycotoxins in Brownies on Raptor ARC-18
This chromatogram may contain analytes that are synonyms of your search terms.
California Cannabis Pesticides and Mycotoxins in Brownies on Raptor ARC-18
Peaks
tR (min)
Precursor Ion
Product Ion 1
Product Ion 2
Polarity
1.
Daminozide-d6
0.6
167.0
149.3
49.3
+
2.
Daminozide
0.7
161.1
44.1
143.2
+
3.
Acephate
1.5
184.0
143.1
95.1
+
4.
Oxamyl
1.8
237.1
72.1
90.1
+
5.
Flonicamid
1.9
230.1
203.1
174.1
+
6.
Methomyl
1.9
163.1
88.1
106.1
+
7.
Thiamethoxam
1.9
292.0
211.1
181.1
+
8.
Imidacloprid
2.2
256.1
209.1
175.1
+
9.
Mevinphos I
2.2
225.1
127.1
193.2
+
10.
Acetamiprid
2.2
223.0
126.1
56.1
+
11.
Dimethoathe-d6
2.2
236.1
205.1
-
+
12.
Dimethoate
2.3
230.0
199.1
125.1
+
13.
Thiacloprid
2.4
253.0
126.0
90.1
+
14.
Mevinphos II
2.4
225.1
127.1
193.2
+
15.
Aflatoxin G2
2.4
331.2
189.3
115.2
+
16.
Aflatoxin G1
2.4
329.2
243.2
215.3
+
17.
Aldicarb
2.5
116.0
89.2
70.2
+
18.
Aflatoxin B2
2.5
315.3
287.2
243.3
+
19.
Dichlorvos
2.6
220.9
109.1
79.2
+
20.
Dichlorvos-d6
2.6
227.0
115.1
-
+
21.
Aflatoxin B1
2.6
313.2
241.2
128.2
+
22.
Imazalil
2.6
297.0
159.0
201.0
+
23.
Carbofuran
2.6
222.1
123.1
165.2
+
24.
Propoxur
2.6
210.1
111.1
93.1
+
25.
Carbaryl-d7
2.7
209.2
152.2
-
+
26.
Carbaryl
2.7
202.1
145.1
127.1
+
27.
Diuron-d6
2.9
239.1
78.2
-
+
28.
Atrazine-d5
2.9
221.2
179.1
-
+
29.
Naled
2.9
397.8
127.1
109.1
+
30.
Metalaxyl
2.9
280.2
220.2
192.2
+
31.
Spiroxamine
2.9
298.3
144.2
100.2
+
32.
Chlorantraniliprole
3.0
483.9
452.9
285.9
+
33.
Phosmet
3.0
318.0
160.1
77.2
+
34.
Azoxystrobin
3.1
404.0
372.1
344.1
+
35.
Linuron-d6
3.1
255.1
160.1
-
+
36.
Fludioxonil
3.2
247.0
180.0
126.0
-
37.
Methiocarb
3.2
226.1
169.1
121.1
+
38.
Dimethomorph I
3.2
388.2
301.2
165.3
+
39.
Boscalid
3.2
342.9
307.1
140.1
+
40.
Paclobutrazol
3.3
294.3
70.1
125.1
+
41.
Malathion
3.3
331.0
127.2
285.2
+
42.
Dimethomorph II
3.4
388.2
301.2
165.3
+
43.
Myclobutanil
3.4
289.1
70.1
125.1
+
44.
Bifenazate
3.4
301.0
198.1
170.2
+
45.
Ochratoxin A
3.5
404.2
239.1
358.3
+
46.
Fenhexamid
3.5
302.1
97.1
55.2
+
47.
Spirotetramat
3.7
374.2
302.1
216.1
+
48.
Ethoprophos
3.8
243.1
131.1
97.1
+
49.
Fipronil
3.8
436.8
331.8
251.9
-
50.
Fenoxycarb
3.9
302.1
88.1
116.1
+
51.
Kresoxim-methyl
4.1
314.2
267.2
222.2
+
52.
Tebuconazole
4.2
308.1
70.1
125.1
+
53.
Diazinon-d10
4.2
315.2
170.2
-
+
54.
Spinosyn A (spinosad)
4.3
732.4
142.2
98.1
+
55.
Diazinon
4.3
305.1
169.2
153.2
+
56.
Coumaphos
4.4
363.1
227.1
307.1
+
57.
Pyridaben
4.4
365.1
309.2
147.2
+
58.
Propiconazole
4.4
342.0
159.0
69.2
+
59.
Clofentezine
4.5
303.0
138.1
102.1
+
60.
Spinosyn D (spinosad)
4.8
746.5
142.3
98.4
+
61.
Spinosyn J (spinetoram)
4.8
748.5
142.3
98.3
+
62.
Trifloxystrobin
4.9
409.2
186.1
145.1
+
63.
Prallethrin
4.9
301.2
123.2
105.2
+
64.
Pyrethrin II
5.2
373.1
161.1
133.2
+
65.
Spinosyn L (spinetoram)
5.4
760.5
142.2
98.1
+
66.
Piperonyl butoxide
5.7
356.3
177.2
119.2
+
67.
Chlorpyrifos
5.8
349.9
198.0
97.1
+
68.
Hexythiazox
5.9
353.1
228.1
168.1
+
69.
Etoxazole
6.4
360.2
141.1
304.2
+
70.
Spiromesifen
6.4
273.2
255.2
187.2
+
71.
Pyrethrin I
6.6
329.2
161.2
105.2
+
72.
Cyfluthrin (qualifier)
6.6
453.1
193.2
-
+
73.
Cyfluthrin
6.6
451.1
191.2
-
+
74.
Cypermethrin
6.8
433.1
191.0
416.0
+
75.
Fenpyroximate
6.8
422.2
366.1
138.1
+
76.
trans-Permethrin
7.4
408.3
183.2
355.1
+
77.
cis-Permethrin
7.7
408.3
183.2
355.1
+
78.
Avermectin B1a
7.7
890.5
305.4
567.4
+
79.
Etofenprox
7.8
394.3
177.2
359.3
+
80.
Bifenthrin
8.0
440.0
181.2
166.2
+
81.
Acequinocyl (precursor ion 1)
9.3
402.3
343.2
189.0
+
82.
Acequinocyl (precursor ion 2)
9.3
386.0
344.2
189.1
+
LC_GN0602
Column
Raptor ARC-18 (cat.# 9314A12)
Dimensions:
100 mm x 2.1 mm ID
Particle Size:
2.7 µm
Pore Size:
90 Å
Guard Column:
Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9314A0252)
Temp.:
40 °C
Sample
California pesticide standard #1 (cat.# 34124)
California pesticide standard #2 (cat.# 34125)
California pesticide standard #3 (cat.# 34126)
California pesticide standard #4 (cat.# 34127)
California pesticide standard #5 (cat.# 34128)
California pesticide standard #6 (cat.# 34129)
Dimethoate-d6 (cat.# 31988)
Dichlorvos-d6 (cat.# 31987)
Carbaryl-d7 (cat.# 31985)
Diazinon-d10 (cat.# 31986)
Atrazine-d5 (cat.# 31984)
Diuron-d6 (cat.# 31989)
Liuron-d6 (cat.# 31990)
Aflatoxins standard (cat.# 34121)
Ochratoxin A (cat.# 34122)
Compounds not present in these mixes were obtained separately.
Diluent:
75:25 Acetonitrile:water
Conc.:
5-15 ng/mL (Expected concentration range in extract of brownie initially spiked at 100 ng/g.)
Inj. Vol.:
2 µL
Mobile Phase
A:
Water, 2 mM ammonium formate, 0.1% formic acid
B:
Methanol, 2 mM ammonium formate, 0.1% formic acid
Time (min)
Flow (mL/min)
%A
%B
0.00
0.5
95
5
1.5
0.5
35
65
8.5
0.5
5
95
9.5
0.5
0
100
10.5
0.5
0
100
10.6
0.5
95
5
12
0.5
95
5
Detector
MS/MS
Ion Mode:
ESI+/ESI-
Mode:
MRM
Instrument
UHPLC
Notes
Brownies were pulverized using a SPEX Freezer/Mill grinder and 0.5 g samples were fortified with pesticides and mycotoxins at 100 ng/g. A mix of internal standards was added at 200 ng/g. 1.5 mL of acetonitrile acidified with 1% acetic acid was added to the sample. The sample was vortexed and sonicated for 5 min, and then the supernatant was passed through a 100 mg Resprep C18 SPE cartridge (cat.# 26030). An additional 1.5 mL of extraction solvent (acidified acetonitrile) was added to the sample pellet, and then the sample was vortexed again. The supernatant was passed through the same C18 cartridge. 750 µL of extract was mixed with 250 µL of water, and then centrifuged for 5 min at low temperature (~7 ⁰C). 2 μL of final extract was injected into the LC-MS/MS system.
Printing tips! To print chromatograms full page, change the print settings in the print dialogue window of your PDF reader software: 1) "fit" or "fit to page", 2) "landscape" for wide chromatograms or "portrait" for tall chromatograms.
Cookies allow for a variety of features that make your visit to Restek more enjoyable. By using this website, you agree to the use of cookies in accordance with our guidelines. For more information, see our privacy policy.
Restek Domestic Customer Service
Thank you
Your message has been sent. We will be in touch shortly.
Message not sent
Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.