1,3-Butadiene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

1,3-Butadiene

CAS # 106-99-0


Compound Structure and Properties

Molecular Weight54.0904
FormulaC4H6
Melting Point-108.9 °C, 164.3 K, -164.0 °F
Boiling Point-4.4 °C, 269 °K, 24 °F
Density0.64 g/cm3 at -6 °C, liquid
Solubility in Water735 ppm
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

1,3-Butadiene; α,γ-Butadiene; trans-Butadiene; Biethylene; Bivinyl; Buta-1,3-diene; Butadiene; Divinyl; Erythrene; Pyrrolylene; Vinylethylene; (E)-CH2=CHCH=CH2; Butadieen; Buta-1,3-dieen; Butadien; Buta-1,3-dien; NCI-C50602; Butadiene * 1,3-Butadiene; CH2=CHCH=CH2; 1,3-Butadiène


Application Chromatograms

TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Hydrocarbon Gases on Rt-Q-BOND
Refinery Gas on Rt-Q-BOND
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
Refinery Gas on Rtx-DHA-100 (ASTM D2163)
Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
C1-C5 Hydrocarbons on Rt-Alumina BOND/MAPD
1,3-Butadiene on Rt-Alumina BOND/MAPD (Purity Analysis)
High Molecular Weight Impurity in 1,3-Butadiene on Rt-Alumina BOND/MAPD
Crude 1,3-Butadiene on Rt-Alumina BOND/MAPD
Styrene Impurities on Stabilwax
Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4
Styrene Impurities Rtx-1701
Mass APH on Rxi-1ms
Refinery Gas on Rt-Alumina BOND/KCl
Refinery Gas
Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na2SO4
Refinery Gas C1 to C5 Using n-Octane on Res-Sil C Packing
Refinery Gas Using OPN on Res-Sil C Packing
Refinery Gas Calibration Standard on Refinery Gas Packed Column Set
Refinery Gas on MXT-Alumina BOND/Na2SO4
Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND/KCl, Rtx-1
Refinery Gas on Rt-Alumina BOND (Na2SO4)

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us