share:
delim
1,2-Dichloroethane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

1,2-Dichloroethane

CAS # 107-06-2


Compound Structure and Properties

Molecular Weight98.9592
FormulaC2H4Cl2
Melting Point-35 °C, 238 °K, -31 °F
Boiling Point84 °C, 357 °K, 183 °F
Density1.253 g/cm³, liquid
Solubility in Water0.87 g/100 mL (20 °C)
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Ethane, 1,2-dichloro-; α,β-Dichloroethane; s-Dichloroethane; Brocide; Dutch liquid; Ethylene chloride; Ethylene dichloride; Freon 150; Glycol dichloride; 1,2-Bichloroethane; 1,2-Dichlorethane; 1,2-Dichloroethane; CH2ClCH2Cl; sym-Dichloroethane; Aethylenchlorid; Bichlorure D'ethylene; Borer sol; Chlorure D'ethylene; Cloruro di ethene; 1,2-DCE; Destruxol borer-sol; 1,2-Dichloorethaan; 1,2-Dichlor-aethan; Dichloremulsion; Di-chlor-mulsion


Application Chromatograms

Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics (Canada) on Rtx-VMS
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
EPA Method 524.2 on Rtx-502.2
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Class 1 Residual Solvents for USP <467> Water-Soluble Articles on Rxi-624Sil MS
Volatiles US EPA Method 624 on Rtx-624
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents Class 1 on Rtx-624
Residual Solvents (Class 1) on Stabilwax (G16)
Residual Solvents Rxi-624Sil MS
Volatile Organics by EPA 8021 on Rtx-VRX
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Solvent Mixture on Rt-Q-BOND
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Residual Solvents (Class 1) for Water-Soluble Articles on Rxi-624Sil MS
Class 1 Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us