share:
delim
m-Xylene/p-Xylene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

M-Xylene

CAS # 108-38-3


Compound Structure and Properties

Molecular Weight106.1650
FormulaC8H10
Melting Point-48 °C, 225 °K, -54 °F
Boiling Point139 °C, 412 °K, 282 °F
Density0.86 g/mL
Solubility in Waterinsoluble
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Benzene, 1,3-dimethyl-; m-Xylene; m-Dimethylbenzene; m-Xylol; 1,3-Dimethylbenzene; 1,3-Xylene; 2,4-Xylene; m-Methyltoluene; meta-Xylene; NSC 61769; 1,3-dimethylbenzene (m-xylene); m-Xylène; m-Xilene

Related Products

Name
m-Xylene
TO-15 65 Component Mix
502.2 MegaMix Standard
8260 MegaMix Calibration Mix
8260 MegaMix Calibration Mix, Revised
TO-14A Calibration Mix
TO-14A Aromatics Mix
TO-14A 41 Component Mix
TO-14A 43 Component Mix
DHA PiONA Standard
DHA PONA Standard
Residual Solvents #1
BTEX Gas Mix
DW-VOC Mix #2
DW-VOC Kit #2 (2,000 µg/mL)
502.2 VOA Calibration Kit #2 (2,000 µg/mL)
502.2 VOA Calibration Kit #3 (200 µg/mL)
502.2 Calibration Mix #4
502.2 VOA Calibration Kit #1 (2,000 µg/mL)
Volatiles MegaMix Standard with Gases
524 Rev. 4.0 Volatile Organics Kit (2,000 µg/mL)
524 Rev. 4.0 VOA Kit #2 (2,000 µg/mL)
Drinking Water VOA MegaMix Standard, 524.2 Rev. 4.1
BTEX Standard
8020A Calibration Mix
8260A Volatile Organics Kit (2,000 µg/mL)
8260 Volatile Organics Kit (2,000 µg/mL)
CLP 04.1 VOA CAL2000 MegaMix Standard
CLP 04.1 VOA Kit #3
CLP VOA CAL2000 MegaMix Standard
VOA Calibration Mix #3
OLC 03.2 VOA MegaMix Standard
PVOC Mix (California)
PVOC/GRO Mix (Wisconsin)
GRO Mix
Certified BTEX in Unleaded Gas Composite Standard
GRO Mix (EPA)
Certified Aromatics in Gasoline
Gasoline Component Standard
Alaska UST Method AK101AA
CA WIP VOA Standard
MA Volatile Petroleum Hydrocarbon (VPH) Standard
MA VPH Standard with Surrogate
MA VPH Matrix Spike Mix with Surrogate
Michigan GRO Mix
MA VPH Standard with Surrogate Rev. 1.1 (July 2004)
MA VPH Matrix Spike Mix with Surrogate Rev. 1.1 (July 2004)
PA DEP UST Standard
WA VPH Standard
European Pharmacopoeia/ICH Class 2 Mix A
BTEX and MTBE Gas Mix
Residual Solvents Class 2 - Mix A
European Pharmacopoeia/ICH Q3C(M) Class 2 Mix A, Revised
8260 MegaMix Calibration Mix Kit
CLP VOA CAL2000 MegaMix Kit
EPA 524.3 Reference Standards
DHA Aromatics Standard
75 Comp TO15 + NJ Mix
74 Comp TO15 + NJ Mix, (no Acrolein)
Residual Solvents Class 2 - Mix A (2013 Rev)

Application Chromatograms

Determination Of Hydrocarbon Group Type in Gasoline on Rxi-1ms by GC-VUV (ASTM D8071)
PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Cumene (Isopropylbenzene) on Rtx-1
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
Impurities in p-Xylene on Stabilwax
Styrene on Stabilwax
Ethylbenzene on Stabilwax
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Aromatics on Rtx-DHA-100 (ASTM D6729-14)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Residual Solvents Class 2 - Mix A (2013 Rev) on Stabilwax (G16)
40 mL of Electronic Cigarette Vapor Collected on a Thermal Desorption Tube and Analyzed on Rtx-VMS
Residual Solvents Class 2 — Mix A on Rxi-624Sil MS (G43) by USP <467>
PAMS 57 Component Mix on Rtx-1 (105 m)
Cannabis Residual Solvents at 50 ppm Cutoff
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Aromatics (Benzene/Toluene/Xylene) on Rtx-200
Aromatics (Benzene/Toluene/Xylene) on MXT-WAX
Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2
Aromatics (Benzene/Toluene/Xylene) on Rtx-Wax
BTEX on Rtx-502.2
Volatile Organics (Canada) on Rtx-VMS
Volatile Organics TO-15 Volatiles on Rtx-1
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)
Custom Solvents Mix on Stabilwax-MS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Alcohols and Acetates on Stabilwax-MS
Volatile Organics US EPA Method 8260B on Rtx-VMS
Reformate on Rtx-1
Alaska Method AK101AA on Rtx-5Sil MS (PID)
Alaska Method AK101AA on Rtx-5Sil MS (FID)
Crude Oil, Prudhoe Bay on Rtx-1
Gasoline Aromatics on Rtx-1
Petroleum Oxygenates on Stabilwax
Gasoline Aromatics on Rtx-1
EPA Method 524.2, Revision 4 Rtx-VMS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
p- and m-Xylenes in Gasoline by GCxGC on Rtx-DHA-150 and Stabilwax
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Styrene Impurities on Stabilwax
EPA Method 524.2 on Rtx-502.2
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
Wisconsin GRO Mix, plus C12 on Rtx-502.2
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)
m- and p-Xylene on Rtx-DHA-150
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Styrene Impurities Rtx-1701
Competitor Comparison: Class 2 - Mix A Residual Solvents for USP <467> Water-Soluble Articles
Aromatics on Rt-TCEP
Mass APH on Rxi-1ms
Aromatics, Aliphatics on 10% TCEP 100/120 Chromosorb® PAW
Aromatics (Xylene Isomers plus Cumene) on 5% RT-1200/1.75% Bentone 34 on 100/120 Silcoport
Aromatics (Xylene Isomers /BTEX) on 5% Rt-1200/5% Bentone 34 on 100/120 Silcoport
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents Class 2 Mixture A on Rtx-624
Residual Solvents (Class 2 - Mixture A) on Stabilwax (G16)
Volatile Organics by EPA 8021 on Rtx-VRX
Ozone Precursors on Rtx-1
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Solvent Mixture on Rt-Q-BOND
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Residual Solvents (Class 2 - Mixture A) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix A Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us