Chlorobenzene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Chlorobenzene

CAS # 108-90-7


Compound Structure and Properties

Molecular Weight112.5569
FormulaC6H5Cl
Melting Point-45 °C, 228 °K, -49 °F
Boiling Point131 °C, 404 °K, 268 °F
Density1.11 g/cm³, liquid
Solubility in Waterlow
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Benzene, chloro-; Chlorobenzene; Monochlorobenzene; MCB; Phenyl Chloride; Benzene chloride; Chlorbenzene; Chlorobenzol; Monochlorbenzene; Chloorbenzeen; Chlorbenzol; Chlorobenzen; Chlorobenzene, mono-; Clorobenzene; Monochloorbenzeen; Monochlorbenzol; Monoclorobenzene; NCI-C54886; Chlorobenzenu; Abluton T30; UN 1134; CP 27; IP Carrier T 40; NSC 8433; Tetrosin SP

Related Products

Name
Chlorobenzene
TO-15 65 Component Mix
502.2 MegaMix Standard
8260 MegaMix Calibration Mix
8260 MegaMix Calibration Mix, Revised
TO-14A Calibration Mix
TO-14A Aromatics Mix
TO-14A 41 Component Mix
TO-14A 43 Component Mix
DW-VOC Mix #2
DW-VOC Kit #2 (2,000 µg/mL)
502.2 VOA Calibration Kit #2 (2,000 µg/mL)
502.2 VOA Calibration Kit #3 (200 µg/mL)
502.2 Calibration Mix #4
502.2 VOA Calibration Kit #1 (2,000 µg/mL)
Volatiles MegaMix Standard with Gases
524 Rev. 4.0 Volatile Organics Kit (2,000 µg/mL)
524 Rev. 4.0 VOA Kit #2 (2,000 µg/mL)
Drinking Water VOA MegaMix Standard, 524.2 Rev. 4.1
602 Purgeable Aromatics Calibration Mix
Volatiles MegaMix Standard, EPA Method 624
624 Calibration Mix #2
624 Kit
624 Complete Kit
418.1 Calibration Mix
TCLP VOA Mix
8010A Calibration Mix #2
8020A Calibration Mix
VOA Purgeable Halocarbon Mix #1
8260 Matrix Spike Mix
8260A Volatile Organics Kit (2,000 µg/mL)
8240/8260 System Performance Check Mix
8260 Volatile Organics Kit (2,000 µg/mL)
VOA Matrix Spike Mix
CLP 04.1 VOA CAL2000 MegaMix Standard
CLP 04.1 VOA Kit #3
CLP VOA CAL2000 MegaMix Standard
VOA Calibration Mix #3
OLC 03.2 VOA MegaMix Standard
CA WIP VOA Standard
European Pharmacopoeia/ICH Class 2 Mix A
Residual Solvents Class 2 - Mix A
European Pharmacopoeia/ICH Q3C(M) Class 2 Mix A, Revised
8260 MegaMix Calibration Mix Kit
CLP VOA CAL2000 MegaMix Kit
Inter-Polar Column Test Mix
EPA 524.3 Reference Standards
75 Comp TO15 + NJ Mix
74 Comp TO15 + NJ Mix, (no Acrolein)
Residual Solvents Class 2 - Mix A (2013 Rev)

Application Chromatograms

4-Hr Shipping Facility Air Sample with radiello 145
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Residual Solvents Class 2 - Mix A (2013 Rev) on Stabilwax (G16)
Residual Solvents Class 2 — Mix A on Rxi-624Sil MS (G43) by USP <467>
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics (Canada) on Rtx-VMS
Volatile Organics TO-15 Volatiles on Rtx-1
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
EPA Method 524.2 on Rtx-502.2
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Competitor Comparison: Class 2 - Mix A Residual Solvents for USP <467> Water-Soluble Articles
Volatiles US EPA Method 624 on Rtx-624
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents Class 2 Mixture A on Rtx-624
Residual Solvents (Class 2 - Mixture A) on Stabilwax (G16)
Residual Solvents Rxi-624Sil MS
Volatile Organics by EPA 8021 on Rtx-VRX
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Solvent Mixture on Rt-Q-BOND
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Residual Solvents (Class 2 - Mixture A) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix A Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us