share:
delim
n-Pentane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Pentane

CAS # 109-66-0


Compound Structure and Properties

Molecular Weight72.1488
FormulaC5H12
Melting Point-130--129 °C, 142.7-144.1 °K, -203--200 °F
Boiling Point36-36 °C, 309-309.4 °K, 97-97 °F
Density0.626 g mL−1
Solubility in Water40 mg L−1 (at 20 °C)
log P3.255
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Pentane; n-Pentane; Skellysolve A; n-C5H12; Pentan; Pentanen; Pentani; Amyl hydride; Pentanen-pentane; C5; NSC 72415


Application Chromatograms

Impurities in Commercial Cyclohexane on Rtx-DHA-100
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
Hydrocarbon Gases on Rt-Q-BOND
Refinery Gas on Rt-Q-BOND
Hydrocarbon Gases on Rt-Q-BOND
4-Hr Shipping Facility Air Sample with radiello 145
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
USP <467> Residual Solvents Class 3 MIx A on Rxi-624Sil MS
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Refinery Gas on Rtx-DHA-100 (ASTM D2163)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Alkylate Standard on Rtx-DHA 50 by Method D5134-13
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Simulated Distillation on Rtx-1 SimDist 2887 DiatoSorb-WHP by ASTM D2887
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-100 (ASTM D5441)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-150 (ASTM D5441)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-50 (ASTM D5441)
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
PAMS 57 Component Mix on Rtx-1 (105 m)
Cannabis Residual Solvents at 50 ppm Cutoff
Solvent Mixture #1 on Rtx-1
Solvent Mixture #1 on Rtx-200
Solvent Mixture #1 on Stabilwax
Solvent Mixture #2 on Rtx-1
Solvent Mixture #2 on Rtx-200
Solvent Mixture #2 on Stabilwax
Solvent Mixture #3 on Rtx-1
Solvent Mixture #3 on Rtx-200
Reformate on Rtx-1
Esters on Stabilwax
Ethers on Rtx-502.2
Aldehydes on Stabilwax
Alcohols Stabilwax
Alcohols Stabilwax
Solvents on Rtx-1
Solvent Mixture #3 on Stabilwax
Alcohols on Rtx-502.2
Alcohols on Rtx-502.2
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
C1-C5 Hydrocarbons on Rt-Alumina BOND/MAPD
1,3-Butadiene on Rt-Alumina BOND/MAPD (Purity Analysis)
Crude 1,3-Butadiene on Rt-Alumina BOND/MAPD
Solvents on Stabilwax
Pentane (lot purity analysis) on MXT-1
Light Hydrocarbons on Rtx-DHA-150
Natural Gas (82% Methane) on Rtx-DHA-150
Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
Solvents on HayeSep Q
Refinery Gas on Rt-Alumina BOND/KCl
Refinery Gas
Sim Dist by ASTM D3710 on Rtx-1 SimDist 2887 (calibration)
Restek PLOT Column Technology Assures Stable Performance Even After 500 Pressure Cycles
Sim Dist, ASTM D3710 (Gasoline) on Rtx-1 SimDist 2887
Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na2SO4
Refinery Gas C1 to C5 Using n-Octane on Res-Sil C Packing
Refinery Gas Calibration Standard on Refinery Gas Packed Column Set
Sulfur Compounds and Hydrocarbons on Rt-XLSulfur
Detailed Hydrocarbon Analysis on Rtx-DHA-100/Rtx-5 DHA Tuning Column
Simulated Distillation (C5-C44) on Rtx-2887
Detailed Hydrocarbons Analysis Rtx-DHA-100
Refinery Gas on MXT-Alumina BOND/Na2SO4
Solvents on Rt-QPLOT
Solvents on Polar Rt-QPLOT
Natural Gas #2 on Rt-QS-BOND
Ozone Precursors on Rtx-1
Volatile Petroleum Hydrocarbons (VPH) Massachusetts Department of Environmental Protection on Rtx-502.2
DHA Column Inertness Comparison Using Oxy Setup
Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND/KCl, Rtx-1
Refinery Gas on Rt-Alumina BOND (Na2SO4)
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us