share:
delim
C6 Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Hexane

CAS # 110-54-3


Compound Structure and Properties

Molecular Weight86.1754
FormulaC6H14
Melting Point-96--94 °C, 177-179 °K, -141--137 °F
Boiling Point68-69 °C, 341.6-342.2 °K, 155-156 °F
Density.6548 g mL−1
Solubility in Water9.5 mg L−1
log P3.764
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Hexane; n-Hexane; Skellysolve B; n-C6H14; Esani; Heksan; Hexanen; Hexyl hydride; Gettysolve-B; NCI-C60571; Exxsol hexane; C6; NSC 68472; Esano


Application Chromatograms

PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Impurities in Commercial Cyclohexane on Rtx-DHA-100
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
Hydrocarbon Gases on Rt-Q-BOND
Refinery Gas on Rt-Q-BOND
4-Hr Shipping Facility Air Sample with radiello 145
16-Hr Laboratory Air Sample with radiello 145
Hexane, MTBE, and TBA on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
TNRCC 1006 Retention Time Marker Mix on Rxi-5Sil MS
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Simulated Distillation on Rtx-1 SimDist 2887 DiatoSorb-WHP by ASTM D2887
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
40 mL of Electronic Cigarette Vapor Collected on a Thermal Desorption Tube and Analyzed on Rtx-VMS
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
PAMS 57 Component Mix on Rtx-1 (105 m)
Cannabis Residual Solvents at 50 ppm Cutoff
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics TO-15 Volatiles on Rtx-1
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Alcohols and Acetates on Stabilwax-MS
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Reformate on Rtx-1
Alaska Method AK101AA on Rtx-5Sil MS (PID)
Alaska Method AK101AA on Rtx-5Sil MS (FID)
Alcohols Stabilwax
Solvents on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Light Hydrocarbons on Rt-Alumina BOND/MAPD
Solvents on Rtx-5
Solvents on Stabilwax
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)
Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4
Flavor Volatiles on Rtx-1
Flavor Volatiles on Stabilwax
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
Solvents on HayeSep Q
Mass APH on Rxi-1ms
Aromatics, Aliphatics on 10% TCEP 100/120 Chromosorb® PAW
Simulated Distillation (Standard Calibration) on MXT-1 SimDist
Refinery Gas
Aromatics (Xylene Isomers plus Cumene) on 5% RT-1200/1.75% Bentone 34 on 100/120 Silcoport
Sim Dist by ASTM D3710 on Rtx-1 SimDist 2887 (calibration)
Restek PLOT Column Technology Assures Stable Performance Even After 500 Pressure Cycles
Sim Dist, ASTM D3710 (Gasoline) on Rtx-1 SimDist 2887
Sulfur Compounds and Hydrocarbons on Rt-XLSulfur
Simulated Distillation (C5-C44) on Rtx-2887
Detailed Hydrocarbons Analysis Rtx-DHA-100
Solvents on MXT-Q-BOND
MXT-Q-BOND Columns are Highly Stable; Pressure Pulsing does not Create Particles or Alter Retention Times
Residual Solvents Class 2 Mixture B on Rtx-624
Solvents on Rt-QPLOT
Residual Solvents (Class 2 - Mixture B) on Stabilwax (G16)
Solvents on Polar Rt-QPLOT
Residual Solvents Rxi-624Sil MS
Refinery Gas #6 on Rt-QS-BOND
Ozone Precursors on Rtx-1
Refinery Gas on Rt-Alumina BOND (Na2SO4)
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Residual Solvents (Class 2 - Mixture B) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix B Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us