Pyridine Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Pyridine

CAS # 110-86-1


Compound Structure and Properties

Molecular Weight79.0999
FormulaC5H5N
Melting Point-41.6 °C, 232 °K, -43 °F
Boiling Point115.2 °C, 388 °K, 239 °F
Density0.9819 g/mL
Solubility in WaterMiscible
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Pyridine; Azabenzene; Azine; NCI-C55301; Piridina; Pirydyna; Pyridin; Rcra waste number U196; Pyr; Pyridine - headspace - from sample -; CP 32; NSC 406123; UN 1282


Application Chromatograms

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Volatile Amine Test Mix on Rtx-Volatile Amine (60 m x 0.32 mm ID)
Substituted Pyridine on Rtx-1701
Substituted Pyridine on Stabilwax
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)
1,4-Dioxane, 2,4-Dinitrophenol, and Pyridine US EPA Method 8270D on Rxi-1ms
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Solvents (Nitrogen Containing) on Rtx-1701
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Uracil, Pyridine, and Phenol on Ultra Aqueous C18
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Amine Test Mix Rtx-35 Amine
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)
Amines & Phenols on Rtx-5 Amine
An Rxi-5ms column provides the most symmetric peak for the basic compound pyridine
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents Class 2 Mixture B on Rtx-624
Residual Solvents (Class 2 - Mixture B) on Stabilwax (G16)
Residual Solvents Rxi-624Sil MS
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Solvent Mixture on Rt-Q-BOND
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Residual Solvents (Class 2 - Mixture B) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix B Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us