share:
delim
2,4-Dichlorophenol Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

2,4-Dichlorophenol

CAS # 120-83-2


Compound Structure and Properties

Molecular Weight163.0014
FormulaC6H4Cl2O
Melting Point42-43 °C, 315-316 °K, 108-109 °F
Boiling Point209-210 °C, 482-483 °K, 408-410 °F
Density1.38g/cm3
Solubility in Water5 g/100mL
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Phenol, 2,4-dichloro-; DCP; Isobac; 2,4-Dichlorophenol; 4,6-Dichlorophenol; NCI-C55345; 1-Hydroxy-2,4-dichlorobenzene; 2,4-DCP; Rcra waste number U081


Application Chromatograms

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Phenols & Benzidines US EPA Methods 604 & 605 on Rtx-5
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Phenols and Benzidines by U.S. EPA Methods 604 and 605 on Rtx-5
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Phenols by EPA Method 604 on Rtx-5
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS
Phenols by EPA 604 on MXT-5
Phenols by EPA Method 604 on Rtx-200

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us