2,4-Dinitrotoluene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

2,4-Dinitrotoluene

CAS # 121-14-2


Compound Structure and Properties

Molecular Weight182.1335
FormulaC7H6N2O4
Melting Point70 °C
Boiling PointDecomposes at 250–300 °C
Density1.52 g/cm3
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Benzene, 1-methyl-2,4-dinitro-; Toluene, 2,4-dinitro-; 2,4-Dinitrotoluene; 2,4-DNT; 1-Methyl-2,4-Dinitrobenzene; 2,4-Dinitrotoluol; NCI-C01865; DNT; Dinitrotoluene; Rcra waste number U105; D.N.T; Dinitrotoluol; 6-Methyl-1,3-dinitrobenzene; 4-Methyl-1,3-dinitrobenzene; NSC 7194; 2,4-Dinitrotoluène


Application Chromatograms

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
EPA Method 525.3 ONP Calibration Standard (with 525.3 Internal and Surrogate Standards) on the Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
Explosives on Raptor ARC-18 by EPA Method 8330B
Explosives on Raptor Biphenyl by EPA Method 8330B
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Aromatics on Raptor Biphenyl
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Nitroaromatics by U.S. EPA Method 609 on Rtx-5
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Explosives by EPA 8330B on Ultra C8 with Trident Direct Guard Column
Explosives by EPA 8330B on Ultra Aromax with Trident Direct Guard
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Semivolatiles on Rxi-5ms by EPA Method 525.2
Explosives by EPA Method 8095 on Rtx-TNT
Explosives US EPA Method 8095 Rtx-TNT2
Explosives Rtx-200
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us