1,4-Dioxane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

1,4-Dioxane

CAS # 123-91-1


Compound Structure and Properties

Molecular Weight88.1051
FormulaC4H8O2
Melting Point11.8 °C, 285 K, 53 °F
Boiling Point101.1 °C, 374 K, 214 °F
Density1.033 g/mL
Solubility in WaterMiscible
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

1,4-Dioxane; p-Dioxane; p-Dioxan; Di(ethylene oxide); Diethylene dioxide; Diethylene ether; Dioxan; Dioxane; Dioxyethylene ether; 1,4-Diethylene dioxide; 1,4-Dioxan; 1,4-Dioxacyclohexane; Glycol ethylene ether; Tetrahydro-p-dioxin; Diokan; Dioksan; Diossano-1,4; Dioxaan-1,4; Dioxan-1,4; Dioxane-1,4; Dioxanne; NCI-C03689; Tetrahydro-1,4-dioxin; p-Dioxin, tetrahydro-; Rcra waste number U108


Application Chromatograms

TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Residual Solvents Class 2 - Mix A (2013 Rev) on Stabilwax (G16)
Residual Solvents Class 2 — Mix A on Rxi-624Sil MS (G43) by USP <467>
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
25 µg/L 8260 MegaMix Revised on Rtx-VMS
Combination Run of U.S. EPA Methods 521 and 522, Nitrosamines and 1,4-Dioxane, on Rxi-5Sil-MS by CSR-LVSI
50 µL CSR-LVSI with 5 ng Nitrosamines, THF, and 1,4-Dioxane On-Column
10 μL CSR-LVSI with 5 ng Nitrosamines, THF, and 1,4-Dioxane On-Column
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
TO-15 65 Component Mix on Rtx-VMS (30 m)
Dynamic Headspace USP <467> solvents on Rtx-1301 (G43)
Volatile Organics TO-15 Volatiles on Rtx-1
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
1,4-Dioxane, 2,4-Dinitrophenol, and Pyridine US EPA Method 8270D on Rxi-1ms
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Ethers on Stabilwax
Ethers on Rtx-502.2
Solvents (Industrial) on Stabilwax-DA
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
1,4-Dioxane in Drinking Water (5 pg On-Column) on Rxi-624Sil MS (Extracted Ion Chromatogram)
EPA 522 Analyte Mix on Rxi-624Sil MS (30 m x 0.25 mm x 1.4 μm)
EPA 522 Analyte Mix on Rtx-624 w/5 m Integra-Guard (30 m x 0.25 mm x 1.4 μm)
Solvents on Rt-QS-BOND
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Competitor Comparison: Class 2 - Mix A Residual Solvents for USP <467> Water-Soluble Articles
USP <467> Residual Solvents on Rtx-1301 (G43) by Static Headspace
Residual Solvents Class 2 Mixture A on Rtx-624
Residual Solvents (Class 2 - Mixture A) on Stabilwax (G16)
Residual Solvents Rxi-624Sil MS
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Solvent Mixture on Rt-Q-BOND
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Residual Solvents (Class 2 - Mixture A) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix A Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us