C10 OH Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Decane

CAS # 124-18-5


Compound Structure and Properties

Molecular Weight142.2817
FormulaC10H22
Melting Point-30--29 °C, 242.7-243.9 °K, -23--21 °F
Boiling Point174-174 °C, 446.9-447.5 °K, 345-346 °F
Density730 mg mL−1
log P5.802
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Decane; n-Decane; n-C10H22; C10; n-Décane; n-Decano; UN 2247

Related Products

Name
n-Decane (C10)
DHA PiONA Standard
DHA PONA Standard
MOSH/MOAH Retention Time Standard
Ozone Precursor Mixture/PAMS
Massachusetts APH Mix
Leaking Underground Storage Tank Retention Time Standard
Retention Time Marker
DRO Mix (Tennessee/Mississippi)
Extraction Retention Time Standard
DRO/ORO Range Calibration Standard
Connecticut ETPH Calibration Mixture
Florida TRPH Standard
MA EPH Aliphatic Hydrocarbon Standard
MA Fractionation Check Mix
MA VPH Standard with Surrogate Rev. 1.1 (July 2004)
MA VPH Matrix Spike Mix with Surrogate Rev. 1.1 (July 2004)
Alternate Boiling Point/Carbon Number Distribution Marker Stock Standard
TNRCC 1006 Retention Time Marker Mix
WA VPH Marker Standard
WA VPH Standard
WA EPH Aliphatic Hydrocarbon Mix
WA EPH Fractionation Check Mix
DRO Mix (EPA/Wisconsin)
D2887 Calibration Mix
D3710-95 Calibration Mix
ASTM D2887-12 Calibration Standard
E1387 Column Resolution Check Mix
E1618 Test Mix
CCME PHC Calibration Mix
System Performance Test Standard Mixture of n-Alkanes
Extraction Solvent Stock Solution #1
Extraction Solvent Stock Solution #2
Grob Test Mix (Capillary GC)
Amine Column Test Mix (GC)
CCME F1 Retention Time Marker
Atlantic RBCA VPH Mix
Atlantic RBCA EPH Mix
Standard Mixture of n-alkanes for System Performance Test
Florida TRPH Standard (HC)
Amine 900 Test Mix
Grob Mix 280
Kovats Test Mix #2
Kovats Test Mix #3
Oxy SetUp Blend
Grob DA 280 Column Test Mix
NJDEP EPH 10/08 Rev. 2 Aliphatics Calibration Standard
NJDEP EPH 10/08 Rev. 2 Aliphatics Matrix Spike Mix
NJDEP EPH 10/08 Rev. 2 Aliphatics Fractionation Check Mix
DHA Paraffins Standard
Qualitative Retention Time Index Standard

Application Chromatograms

PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
Petroleum Hydrocarbons (TPH) on Rxi-1ms
TNRCC 1006 Retention Time Marker Mix on Rxi-5Sil MS
NJ DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
MA DEP EPH Aliphatics on Rxi-5Sil MS
NJ DEP EPH Aliphatics on Rxi-5Sil MS
MA DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Simulated Distillation on Rtx-1 SimDist 2887 DiatoSorb-WHP by ASTM D2887
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
Arabian Medium Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
DRO/ORO Calibration Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
South Louisiana Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 11 on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
DRO/ORO Calibration Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
South Louisiana Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Iraqi Basrah Light Crude Oil on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 11 on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Arabian Medium Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Iraqi Basrah Light Crude Oil on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard Mix on Rxi-1HT
PAMS 57 Component Mix on Rtx-1 (105 m)
Lubricant (Synthetic) on Stabilwax
Reformate on Rtx-1
Alaska Method AK101AA on Rtx-5Sil MS (PID)
Alaska Method AK101AA on Rtx-5Sil MS (FID)
Crude Oil, Arabian Light on Rtx-1
Crude Oil, Prudhoe Bay on Rtx-1
Alcohols Stabilwax
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
Amine Test Mix Rtx-35 Amine
C10-C40 Alkanes on Rxi-5HT
Low Bleed, High Efficiency MXT-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
n-Alkanes on Rtx-Mineral Oil
Hydrocarbons (C7-C42) on Rtx-1
Mass APH on Rxi-1ms
Aromatics, Aliphatics on 10% TCEP 100/120 Chromosorb® PAW
Simulated Distillation (Standard Calibration) on MXT-1 SimDist
Diesel & Motor Oil on Rtx-Mineral Oil
n-alkanes (C10-C40) on Rtx-Mineral Oil
Aromatics (Xylene Isomers plus Cumene) on 5% RT-1200/1.75% Bentone 34 on 100/120 Silcoport
Sim Dist by ASTM D3710 on Rtx-1 SimDist 2887 (calibration)
Sim Dist, ASTM D3710 (Gasoline) on Rtx-1 SimDist 2887
DRO Mix on Rtx-5
Uber Test Mix on Rxi-5Sil MS
Hydrocarbons (C10-C44) on MXT-1HT SimDist
Simulated Distillation (C5-C44) on Rtx-2887
Detailed Hydrocarbons Analysis Rtx-DHA-100
NJDEP EPH Aliphatic Fraction on Rtx-5
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us