share:
delim
Dimethyl phthalate Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Dimethyl phthalate

CAS # 131-11-3


Compound Structure and Properties

Molecular Weight194.1840
FormulaC10H10O4
Melting Point2 °C, 275 °K, 36 °F
Boiling Point283 - 284 °C
Density1.19 g/cm3
Solubility in WaterSlightly soluble
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Dimethyl phthalate; Phthalic acid, dimethyl ester; Avolin; DMF, Insect repellent; DMP; Fermine; Mipax; NTM; Palatinol M; Solvanom; Solvarone; Unimoll DM; Dimethyl orthophthalate; Methyl phthalate; Dimethyl benzene-o-dicarboxylate; Dimethyl o-phthalate; ENT 262; Phthalic acid methyl ester; Phthalsaeuredimethylester; Dimethyl 1,2-benzendicarboxylate; Kemester DMP; Kodaflex DMP; Repeftal; Uniplex 110; 1,2-Benzenedicarboxylic acid, dimethyl ester


Application Chromatograms

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
EPA and EU Phthalates on Rtx-CLPesticides2
EPA and EU Phthalates on Rtx-50
EPA and EU Phthalates on Rtx-CLPesticides
EPA and EU Phthalates on Rxi-5ms
Phthalates on Rxi-XLB (Extended List)
EPA and EU Phthalates on Rxi-XLB
EPA and EU Phthalates on Rtx-440
Phthalates (50 µg/mL) on Rtx-440 (Extended List, Full Scan Mode)
EPA and EU Phthalates on Rxi-35Sil MS
EPA Method 8061A Phthalates on Rtx-440
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
EPA Method 8060 Phthalate Esters on Rtx-5 (Direct Injection)
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Phthalate Esters by U.S. EPA Method 606 on MXT-5
Phthalate Esters by U.S. EPA Method 606 on Rtx-5
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Semivolatiles on Rxi-5ms by EPA Method 525.2
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us