Methyl tert-butyl ether Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis
Find another compound:
Methyl tert-butyl ether CAS # 1634-04-4
Compound Structure and Properties Molecular Weight 88.1482 Formula C5 H12 O Melting Point -109 °C, 164 °K, -164 °F Boiling Point 55.2 °C, 328 °K, 131 °F Density 0.7404 g/cm³ Solubility in Water 26 g/L (20 °C)
GC Mass Spectrum
m/zClick and drag to zoom, double click to reset zoom Hover over end of line for value.
Synonyms Propane, 2-methoxy-2-methyl-; Ether, tert-butyl methyl; tert-Butyl methyl ether; Methyl tert-butyl ether; 2-Methoxy-2-methylpropane; 2-Methyl-2-methoxypropane; tert-C4H9OCH3; Methyl t-butyl ether; MTBE; Methyl 1,1-dimethylethyl ether; Driveron; methyl tert-butyl ether (MTBE); 1,1-Dimethylethyl methyl ether; t-Butyl methyl ether; Méthyl tert-butyl éther; Metil-ter-butil-etere
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Hexane, MTBE, and TBA on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
USP <467> Residual Solvents Class 3 MIx A on Rxi-624Sil MS
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Oxygenates on Rtx-VMS
Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2
Petroleum Oxygenates (MTBE) on Rtx-1
Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Gasoline Range Organics Oxygenates Rtx-VMS
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Petroleum Oxygenates on Rt-TCEP
Mass APH on Rxi-1ms
Detailed Hydrocarbons Analysis Rtx-DHA-100
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8021 on Rtx-VRX
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Volatile Petroleum Hydrocarbons (VPH) Massachusetts Department of Environmental Protection on Rtx-502.2
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)