share:
delim
Benz[b]fluoranthene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Benzo(b)fluoranthene

CAS # 205-99-2


Compound Structure and Properties

Molecular Weight252.3093
FormulaC20H12
Melting Point168 °C
Density1.286 g/cm3
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Benz[e]acephenanthrylene; Benzo[b]fluoranthene; Benzo[e]fluoranthene; 2,3-Benzofluoranthrene; benzo[e]acephenanthrylene; B(b)F; 2,3-Benzofluoranthene; 4,5-Benzofluoranthene; 2,3-Benzfluoranthene; 3,4-Benzofluoranthene; 3,4-benzfluoranthene; Benz[b]fluoranthene; 3,4-Benz[e]acephenanthrylene; NSC 89265; Benzo(b)fluoranthène; Benzo(b)fluorantene


Application Chromatograms

MA DEP EPH Aromatics on Rxi-5Sil MS
NJ DEP EPH Aromatics on Rxi-5Sil MS
MA DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
NJ DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
Resolution of Benzo Fluoranthene and Benzo Pyrene Isomers on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)
Select PAHs on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)
Semivolatiles on Rxi-5ms (Split Injection)
EPA 8310 PAHs on Pinnacle II PAH by LC-UV
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH (30 m x 0.25 mm ID x 0.10 µm df )
NIST SRM 1975, Diesel Particulate Extract, on Rxi-PAH
Automated Solvent Extraction of NIST SRM 1941b, Organics in Marine Sediment, on Rxi-PAH
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH
Detailed Analysis of Polycyclic Aromatic Hydrocarbons (PAHs) in Creosote Oil on Rxi-PAH
Polycyclic Aromatic Hydrocarbons (PAHs) in a Spring Creek Sediment Sample by GCxGC-TOFMS
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)
PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)
Benzo[b]fluoranthene and Benzo[a]pyrene in a QuEChERS Extract of Mate Tea Separated from Potential Interfering PAHs on Rxi-PAH
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Coal Tar PAHs on Rxi-PAH (40 m x 0.18 mm x 0.07 µm)
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
NIST SRM 2260a PAH Mix on Rxi-PAH
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-CLPesticides2
Polynuclear Aromatic Hydrocarbons US EPA Method 8100 on MXT-5
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-5
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx-440
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
PAHs and PCB Congeners on Rxi-XLB
EU 15+1 PAH Mix on Pinnacle DB PAH
EU 15+1 PAHs on Pinnacle II PAH (UV/Vis)
EPA 8310 PAH Mix on Pinnacle II PAH (FLD)
EPA 8310 PAH Mix on Pinnacle DB PAH
EU 15+1 PAHs on Pinnacle II PAH (FLD)
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Polycyclic Aromatic Hydrocarbons on Rtx-50
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS
Polycyclic Aromatic Hydrocarbons on Rxi-17
Polycyclic Aromatic Hydrocarbons on Rxi-17 column
Polycyclic Aromatic Hydrocarbons on Rxi-17 (15m x 0.25mm x 0.25µm)
Benzofluoranthenes on Rxi-17 (15m x 0.25mm x 0.25µm)
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
Polycyclic Aromatic Hydrocarbons by EPA Method 610 on Rxi-5ms
Benzofluoranthenes on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
Semivolatiles on Rxi-5ms by EPA Method 525.2
EPA Method 610 Polycyclic Aromatic Hydrocarbons on Pinnacle DB PAH
QuEChERS Extract of NIST SRM 2974a Freeze-Dried Mussel Tissue (GCxGC contour plot)
Polycyclic Aromatic Hydrocarbons Infant Formula with and without QuEChERS dSPE Clean-up on Rxi-5Sil MS
NJDEP EPH Aromatics on Rtx-5
Polycyclic Aromatic Hydrocarbons by EPA 610 on Rxi-5ms
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS
Polycyclic Aromatic Hydrocarbons Rxi-5Sil MS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us