4-bromo-1-fluorobenzene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

4-bromo-1-fluorobenzene

CAS # 460-00-4


Compound Structure and Properties

Molecular Weight174.9984
FormulaC6H4BrF
Data above sourced from ChemSpider

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

p-Bromofluorobenzene; p-Fluorobromobenzene; BFB; Benzene, 1-bromo-4-fluoro-; p-Fluorophenyl bromide; 1-Bromo-4-fluorobenzene; 1-Fluoro-4-bromobenzene; 4-Bromofluorobenzene; 4-Fluoro-1-bromobenzene; 4-Fluorobromobenzene; 4-Fluorophenyl bromide; 4-Bromo-1-fluorobenzene; NSC 10268; 1-Bromo-4-fluorobenzène


Application Chromatograms

PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
PAMS 57 Component Mix on Rtx-1 (105 m)
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
Trimethylsilanol on Rtx-VMS (30 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Custom Cleaning Solvents Standard on Stabilwax-MS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
Alaska Method AK101AA on Rtx-5Sil MS (PID)
Alaska Method AK101AA on Rtx-5Sil MS (FID)
EPA Method 524.2, Revision 4 Rtx-VMS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-5
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-200
Mass APH on Rxi-1ms
Volatiles US EPA Method 624 on Rtx-624
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us