Limonene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Limonene

CAS # 5989-27-5


Compound Structure and Properties

Molecular Weight136.2340
FormulaC10H16
Melting Point-74.35 °C, 199 °K, -102 °F
Boiling Point176 °C, 449 °K, 349 °F
Density0.8411 g/cm³
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

D-Limonene; p-Mentha-1,8-diene, (R)-(+)-; (+)-(R)-Limonene; (+)-(4R)-Limonene; (+)-p-Mentha-1,8-diene; (+)-Limonene; Carvene; D-(+)-Limonene; (+)-Dipentene; Limonene, (+)-; Dextro-limonene; (γ)-Carvene; p-Mentha-1,8-diene; R(γ)-Limonene; Cyclohexene, 1-methyl-4-(1-methylethenyl)-, (R)-; (R)-(+)-Limonene; Limonene, (D)-; (R)-1-methyl-4-(1-methylethenyl)cyclohexene; (R)-4-Isopropenyl-1-methyl-1-cyclohexene; 4-Isopropenyl-1-methyl-1-cyclohexene-, (R)-; (R)-Limonene; (4R)-(+)-Limonene; (4R)-Limonene; (R)-(+)-p-Mentha-1,8-diene; (R)-p-Mentha-1,8-diene


Application Chromatograms

Citronella Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Bergamot Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Lemon Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Peppermint Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Grapefruit Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Tea Tree Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Citronella Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Tea Tree Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Peppermint Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lavender Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Patchouli Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Bergamot Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lemon Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Grapefruit Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lavender Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Patchouli Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Lemongrass Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lemongrass Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Citronella Java Oil on Rtx-Wax
Bergamot Oil on Rtx-Wax
Eucalyptus Oil on Rtx-Wax
Lavender Oil on Rtx-Wax
Peppermint Oil on Rtx-Wax
Grapefruit Oil on Rtx-Wax
Tea Tree Oil on Rtx-Wax
Lemongrass Oil on Rtx-Wax
Lemon Oil on Rtx-Wax
Bergamot Oil on Rxi-5Sil MS
Lemon Oil on Rxi-5Sil MS
Patchouli Oil on Rxi-5Sil MS
Lavender Oil on Rxi-5Sil MS
Citronella Oil on Rxi-5Sil MS
Eucalyptus Oil on Rxi-5Sil MS
Peppermint Oil on Rxi-5Sil MS
Grapefruit Oil on Rxi-5Sil MS
Tea Tree Oil on Rxi-5Sil MS
Lemongrass Oil on Rxi-5Sil MS
Cannabis Terpenes Standard #1 & #2 on Rxi-624Sil MS
16-Hr Laboratory Air Sample with radiello 145
Terpene Profile of Citra Hops on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Parsley on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Sage on Rxi-624Sil MS by FET-HS-GC
Medical Cannabis Terpenes on Rxi-624Sil MS
Cannabis Terpenes on Rxi-624Sil MS by FET-HS-GC
Terpenes in Kryptonite Medical Cannabis on Rxi-624Sil MS
Terpenes in Kryptonite Cannabis on Rxi-624Sil MS
Terpenes in Blueberry Jack Cannabis on Rxi-624Sil MS
Terpenes in Blueberry Jack Medical Cannabis on Rxi-624Sil MS
Terpenes in Kryptonite Medical Cannabis on Rxi-624Sil MS
Terpenes in Blueberry Jack Medical Cannabis on Rxi-624Sil MS
Two Brands of Gin on Stabilwax-MS (Overlay)
Bergamot Oil Rtx-5Sil MS by GC/MS
Bergamot Oil Fast GC/MS on Rtx-5
Bergamot Flavor on Rt-βDEXse

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us