Dimethoate Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Dimethoate

CAS # 60-51-5


Compound Structure and Properties

Molecular Weight229.2574
FormulaC5H12NO3PS2
Melting Point43–45 °C (316–318 K)
Boiling Point117 °C (390 K) at 10 Pa
Density1.3 g/cm3, solid
Solubility in Water2.5 g/100 ml
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Dimethoate; American Cyanamid 12,880; BI 58; Cygon; Cygon Insecticide; Cygon 4E; CL 12880; Daphene; De-Fend; Dimeton; Dimevur; Experimental Insecticide 12,880; ENT-24650; Fosfatox R; Fosfotox; Fosfotox R; Fosfotox R 35; Fostion MM; FIP; Lurgo; Maxima Phlanzenschutz; Perfecthion; Perfekthion; Phosphamid; Phosphamide


Application Chromatograms

LC Multiresidue Pesticide Mix Extracted from Celery with QuEChERS Slim Pouch on Raptor ARC-18 by LC-MS/MS
LC Multiresidue Pesticide Mix Extracted from Brown Rice Flour with QuEChERS Slim Pouch on Raptor ARC-18 by LC-MS/MS
QuEChERS Performance Standards Kit Pesticides on Rxi-5ms
GCxGC-TOFMS Contour Plot of Unfortified Detoxification Tea
GCxGC-TOFMS Contour Plot Showing Potential Isobaric Interference with Acephate (m/z 136) in 1D Analysis
GCxGC-TOFMS Contour Plot of Unfortified Berry Tea
LC Multiresidue Pesticide Standard #1 on Raptor ARC-18 by LC-MS/MS
GCxGC-TOFMS Analysis of Multi-Pesticide Standard Using Rxi-5Sil MS and Rtx-200
LC Multiresidue Pesticide Standard #1 on Ultra Aqueous C18 by LC-MS/MS
Nitrogen/Phosphorus Pesticides & Herbicides on Rtx-5
EPA Method 8140/8141/8141A Organophosphorus Pesticides on Rtx-35
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-1701
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-1
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-35
Incurred Pesticides in Red Bell Pepper QuEChERS Extract on Ultra Aqueous C18
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Red Bell Pepper Showing Incurred Pesticides Using Rxi-5Sil MS and Rtx-200
Marijuana Pesticides by GCxGC on Rxi-5Sil MS and Rtx-200
Organophosphorus Pesticides (European) on Rtx-CLPesticides
Organophosphorus Pesticides (European) on Rtx-CLPesticides
Organophosphorous Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides & Rtx-OPPesticides2
Pesticides on Pinnacle DB Aqueous C18
Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS
Organophosphorus Pesticides by EPA Method 8140/8141/8141A on Rtx-CLPesticides
Organophosphorus Pesticides by US EPA Method 8140/8141/8141A on Rtx-CLPesticides2
Organophosphorus Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides2
Pesticides on Ultra Aqueous C18

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us