Benzene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Benzene

CAS # 71-43-2


Compound Structure and Properties

Molecular Weight78.1118
FormulaC6H6
Melting Point5.5 °C, 278.7 K
Boiling Point80.1 °C, 353.3 K
Density0.8765(20) g/cm3
Solubility in Water1.8 g/L (15 °C)
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Benzene; [6]Annulene; Benzol; Benzole; Coal naphtha; Cyclohexatriene; Phenyl hydride; Pyrobenzol; Pyrobenzole; Benzolene; Bicarburet of hydrogen; Carbon oil; Mineral naphtha; Motor benzol; Benzeen; Benzen; Benzin; Benzine; Benzolo; Fenzen; Nitration benzene; NCI-C55276; Phene; Rcra waste number U019; Annulene

Related Products

Name
ASTM D3606 Calibration Kit without Internal Standard
ASTM D3606 Calibration Kit with MEK Internal Standard
ASTM D3606 Calibration Kit with sec-Butanol Internal Standard
502.2 MegaMix Standard
8260 MegaMix Calibration Mix
8260 MegaMix Calibration Mix, Revised
DHA PiONA Standard
DHA PONA Standard
Residual Solvents #1
DW-VOC Mix #1
DW-VOC Kit #2 (2,000 µg/mL)
502.2 VOA Calibration Kit #2 (2,000 µg/mL)
502.2 VOA Calibration Kit #3 (200 µg/mL)
502.2 Calibration Mix #4
502.2 VOA Calibration Kit #1 (2,000 µg/mL)
Volatiles MegaMix Standard with Gases
524 Rev. 4.0 Volatile Organics Kit (2,000 µg/mL)
524 Rev. 4.0 VOA Kit #2 (2,000 µg/mL)
Drinking Water VOA MegaMix Standard, 524.2 Rev. 4.1
602 Purgeable Aromatics Calibration Mix
Volatiles MegaMix Standard, EPA Method 624
624 Calibration Mix #2
624 Kit
624 Complete Kit
TCLP VOA Mix
BTEX Standard
8020A Calibration Mix
8260 Matrix Spike Mix
8260A Volatile Organics Kit (2,000 µg/mL)
8260 Volatile Organics Kit (2,000 µg/mL)
VOA Matrix Spike Mix
CLP 04.1 VOA CAL2000 MegaMix Standard
CLP 04.1 VOA Kit #3
CLP VOA CAL2000 MegaMix Standard
VOA Calibration Mix #2
OLC 03.2 VOA MegaMix Standard
PVOC Mix (California)
PVOC/GRO Mix (Wisconsin)
GRO Mix
Certified BTEX in Unleaded Gas Composite Standard
GRO Mix (EPA)
Certified Aromatics in Gasoline
Gasoline Component Standard
Alaska UST Method AK101AA
CA WIP VOA Standard
MA Volatile Petroleum Hydrocarbon (VPH) Standard
MA VPH Standard with Surrogate
MA VPH Matrix Spike Mix with Surrogate
Michigan GRO Mix
MA VPH Standard with Surrogate Rev. 1.1 (July 2004)
MA VPH Matrix Spike Mix with Surrogate Rev. 1.1 (July 2004)
PA DEP UST Standard
WA VPH Standard
European Pharmacopoeia/ICH Class 1 Mix
European Pharmacopoeia/ICH Class 1 Mix (revised)
USP <467> Calibration Mixture #4
USP <467> Calibration Mixture #5
USP <467> Calibration Mixture #3
LC Normal Phase Test Mix #1
LC Reversed Phase Test Mix #1
Atlantic RBCA VPH Mix
8260 MegaMix Calibration Mix Kit
CLP VOA CAL2000 MegaMix Kit
Kovats Probes Test Standard
Residual Solvents - Class 1
Kovats Test Mix #1
Kovats Test Mix #2
Kovats Test Mix #3
Oxy SetUp Blend
ASTM D3606 Calibration Standard #1 without Internal Standard
ASTM D3606 Calibration Standard #2 without Internal Standard
ASTM D3606 Calibration Standard #3 without Internal Standard
ASTM D3606 Calibration Standard #4 without Internal Standard
ASTM D3606 Calibration Standard #5 without Internal Standard
ASTM D3606 Calibration Standard #6 without Internal Standard
ASTM D3606 Calibration Standard #7 without Internal Standard
ASTM D3606 Calibration Standard #1 with MEK Internal Standard
ASTM D3606 Calibration Standard #2 with MEK Internal Standard
ASTM D3606 Calibration Standard #3 with MEK Internal Standard
ASTM D3606 Calibration Standard #4 with MEK Internal Standard
ASTM D3606 Calibration Standard #5 with MEK Internal Standard
ASTM D3606 Calibration Standard #6 with MEK Internal Standard
ASTM D3606 Calibration Standard #7 with MEK Internal Standard
ASTM D3606 Calibration Standard #1 with sec-Butanol Internal Standard
ASTM D3606 Calibration Standard #2 with sec-Butanol Internal Standard
ASTM D3606 Calibration Standard #3 with sec-Butanol Internal Standard
ASTM D3606 Calibration Standard #4 with sec-Butanol Internal Standard
ASTM D3606 Calibration Standard #5 with sec-Butanol Internal Standard
ASTM D3606 Calibration Standard #6 with sec-Butanol Internal Standard
ASTM D3606 Calibration Standard #7 with sec-Butanol Internal Standard
ASTM D3606 Quality Control Standard with sec-Butanol Internal Standard
Benzene
EPA 524.3 Reference Standards
DHA Aromatics Standard

Application Chromatograms

PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Thiophene in Benzene on Rtx-Wax
Impurities in Commercial Cyclohexane on Rtx-DHA-100
Cumene (Isopropylbenzene) on Rtx-1
Impurities in α-Methylstyrene on Rtx-1
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
Impurities in p-Xylene on Stabilwax
Styrene on Stabilwax
Ethylbenzene on Stabilwax
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
4-Hr Shipping Facility Air Sample with radiello 145
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Aromatics on Rtx-DHA-100 (ASTM D6729-14)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
40 mL of Electronic Cigarette Vapor Collected on a Thermal Desorption Tube and Analyzed on Rtx-VMS
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
PAMS 57 Component Mix on Rtx-1 (105 m)
Cannabis Residual Solvents at 50 ppm Cutoff
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
Aromatics on Raptor Biphenyl
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Substituted Pyridine on Rtx-1701
Substituted Pyridine on Stabilwax
Aromatics (Benzene/Toluene/Xylene) on Rtx-200
Aromatics (Benzene/Toluene/Xylene) on MXT-WAX
Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2
Aromatics (Benzene/Toluene/Xylene) on Rtx-Wax
Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1
Spark Ignition Fuel Aromatics D3606 Column Set
Dynamic Headspace USP <467> solvents on Rtx-1301 (G43)
BTEX on Rtx-502.2
Volatile Organics (Canada) on Rtx-VMS
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Solvent Mixture #1 on Rtx-1
Solvent Mixture #1 on Rtx-200
Solvent Mixture #1 on Stabilwax
Solvent Mixture #2 on Rtx-1
Solvent Mixture #2 on Rtx-200
Solvent Mixture #2 on Stabilwax
Solvent Mixture #3 on Rtx-1
Solvent Mixture #3 on Rtx-200
Volatile Organics US EPA Method 8260B on Rtx-VMS
Reformate on Rtx-1
Alaska Method AK101AA on Rtx-5Sil MS (PID)
Alaska Method AK101AA on Rtx-5Sil MS (FID)
Crude Oil, Prudhoe Bay on Rtx-1
Gasoline Aromatics on Rtx-1
Petroleum Oxygenates on Stabilwax
Gasoline Aromatics on Rtx-1
EPA Method 524.2, Revision 4 Rtx-VMS
Solvents on Rtx-1
Solvent Mixture #3 on Stabilwax
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Benzalkonium Chloride Compounds on Ultra IBD
Separation of Ethanol and Aromatics from Paraffins in Gasoline with GCxGC on Rtx-DHA-150 and Stabilwax
Gasoline Containing Ethanol on D3606 Application Column Set by ASTM D3606-10 (Modified)
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
Solvents on Stabilwax
EPA Method 524.2 on Rtx-502.2
Wisconsin GRO Mix, plus C12 on Rtx-502.2
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Class 1 Residual Solvents for USP <467> Water-Soluble Articles on Rxi-624Sil MS
Aromatics on Rt-TCEP
Mass APH on Rxi-1ms
Aromatics, Aliphatics on 10% TCEP 100/120 Chromosorb® PAW
Volatiles US EPA Method 624 on Rtx-624
Aromatics (Xylene Isomers plus Cumene) on 5% RT-1200/1.75% Bentone 34 on 100/120 Silcoport
Aromatics (Xylene Isomers /BTEX) on 5% Rt-1200/5% Bentone 34 on 100/120 Silcoport
Detailed Hydrocarbons Analysis Rtx-DHA-100
USP <467> Residual Solvents on Rtx-1301 (G43) by Static Headspace
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Gasoline on ASTM D3606 Application Column Set
Residual Solvents Class 1 on Rtx-624
Residual Solvents (Class 1) on Stabilwax (G16)
Solvents on Rt-QPLOT
Residual Solvents Rxi-624Sil MS
Volatile Organics by EPA 8021 on Rtx-VRX
Ozone Precursors on Rtx-1
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Volatile Petroleum Hydrocarbons (VPH) Massachusetts Department of Environmental Protection on Rtx-502.2
Solvent Mixture on Rt-Q-BOND
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Residual Solvents (Class 1) for Water-Soluble Articles on Rxi-624Sil MS
Class 1 Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS
Food Packaging Volatiles on Rtx-5MS
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us