Methane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Methane

CAS # 74-82-8


Compound Structure and Properties

Molecular Weight16.0425
FormulaCH4
Melting Point-182 °C, 90.7 °K, -296 °F
Boiling Point-164--160 °C, 109-113 °K, -263--256 °F
Density655.6 μg mL−1
Solubility in Water22.7 mg L−1
log P1.09
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Methane; Marsh gas; Methyl hydride; CH4; Fire damp; R 50; Biogas; UN 1971; UN 1972


Application Chromatograms

Permanent Gases on Rt-Msieve 5A (15 m x 0.53 mm x 50 μm)
Permanent Gases on Rt-Msieve 5A (15 m x 0.25 mm x 20 μm)
Permanent Gases on Rt-Msieve 5A (15 m x 0.32 mm x 30 μm)
Permanent Gases and Nitrous Oxide on Rt-Msieve 5A
Permanent Gases and Nitrous Oxide on ShinCarbon ST Micropacked Column
Permanent Gases and Nitrous Oxide on Rt-Alumina BOND/Na2SO4
Permanent Gases and Nitrous Oxide on Rt-Q-BOND
Hydrocarbon Gases on Rt-Q-BOND
Refinery Gas on Rt-Q-BOND
Hydrocarbon Gases on Rt-Q-BOND
Permanent Gases on Capillary Rt-MSieve 5A
Refinery Gas on Rtx-DHA-100 (ASTM D2163)
Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)
Butane Fuel on Rtx-1
Butane Fuel on Rtx-1
Propane Fuel on Rtx-1
Methane Purity on Rtx-1
C1-C5 Hydrocarbons on Rt-Alumina BOND/MAPD
Gasoline Light Fractions on Rtx-DHA-150
Light Hydrocarbons on Rtx-DHA-150
Natural Gas (82% Methane) on Rtx-DHA-150
Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4
Ethylene Purity Analysis using ASTM D6159-97
Permanent Gases on Molecular Sieve 5A and Molecular Sieve 13X
Permanent Gases Rt-Q-BOND
Propane Camping Fuel on Rt-Alumina BOND/KCl
Refinery Gas on Rt-Alumina BOND/KCl
Refinery Gas
Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na2SO4
Refinery Gas C1 to C5 Using n-Octane on Res-Sil C Packing
Refinery Gas Using OPN on Res-Sil C Packing
Refinery Gas Calibration Standard on Refinery Gas Packed Column Set
Sulfur Compounds and Hydrocarbons on Rt-XLSulfur
Propane Camping Fuel on Rt-Alumina BOND/Na2SO4
Butane Lighter Fluid on Rt-Alumina BOND/Na2SO4
Water and Ethanol in Acetone on Rt-Q-BOND
Permanent Gases on MXT-Msieve 5A
Refinery Gas on MXT-Alumina BOND/Na2SO4
Solvents on MXT-Q-BOND
Permanent Gases on ShinCarbon ST (micropacked)
MXT-Q-BOND Columns are Highly Stable; Pressure Pulsing does not Create Particles or Alter Retention Times
Solvents on Rt-QPLOT
Permanent Gases Rt-Msieve 5A
Solvents on Polar Rt-QPLOT
Natural Gas #2 on Rt-QS-BOND
Butane Lighter Fluid Rt-Alumina BOND/KCl
Refinery Gas #6 on Rt-QS-BOND
Refinery Gas Mix on Rt-QS-BOND
Q, QS, S, and U PLOT Column Comparison
Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND/KCl, Rtx-1
Refinery Gas on Rt-Alumina BOND (Na2SO4)
Permanent Gases and C1+C2 Hydrocarbons on ShinCarbon ST (micropacked)
Hydrocarbon Gases on HayeSep® S (micropacked)

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us