share:
delim
t-Butanol Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Tert-Butyl alcohol

CAS # 75-65-0


Compound Structure and Properties

Molecular Weight74.1216
FormulaC4H10O
Melting Point25-26 °C, 298-299 °K, 77-79 °F
Boiling Point82-83 °C, 355-356 °K, 179-181 °F
Density0.775 g/mL
Solubility in Watermiscible
log P0.584
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

2-Propanol, 2-methyl-; tert-Butyl Alcohol; tert-Butanol; Ethanol, 1,1-Dimethyl-; Trimethylcarbinol; Trimethylmethanol; 1,1-Dimethylethanol; 2-Methyl-2-propanol; tert-C4H9OH; t-Butanol; tert-Butyl hydroxide; 2-Methylpropanol-2; 2-Methylpropan-2-ol; Alcool butylique tertiaire; Butanol tertiaire; t-Butyl hydroxide; Methanol, trimethyl-; NCI-C55367; 2-Methyl n-propan-2-ol; Methyl-2 propanol-2; t-Butyl alcohol; Terz-butanolo


Application Chromatograms

TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-100 (ASTM D5441)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-150 (ASTM D5441)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-50 (ASTM D5441)
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
Oxygenates on Rtx-VMS
Petroleum Oxygenates (MTBE) on Rtx-1
Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Volatile Organics US EPA Method 8260B on Rtx-VMS
Alcohols Stabilwax
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
BAC Resolution Control Standard t-B on Rtx-BAC Plus 1 and Plus 2 Column Set
Blood Alcohol Analysis on Rtx-BAC Plus 2
Blood Alcohol Analysis on Rtx-BAC Plus 1
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Petroleum Oxygenates on Rt-TCEP
Detailed Hydrocarbon Analysis on Rtx-DHA-100/Rtx-5 DHA Tuning Column
Detailed Hydrocarbons Analysis Rtx-DHA-100
Alkyl Nitrites on Rtx-BAC1 and Rtx-BAC2 (dual column)
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
DHA Column Inertness Comparison Using Oxy Setup
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
Cleaning Solvents on Rtx-VMS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us