share:
delim
Hexachlorocyclopentadiene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Hexachlorocyclopentadiene

CAS # 77-47-4


Compound Structure and Properties

Molecular Weight272.7715
FormulaC5Cl6
Melting Point−10 °C
Boiling Point239 °C
Density1.702 g/cm3
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

C 56; Cyclopentadiene, Hexachloro-; Graphlox; Hexachloro-1,3-cyclopentadiene; Hexachlorocyclopentadiene; HRS 1655; Perchlorocyclopentadiene; 1,3-Cyclopentadiene, hexachloro-; Hexachlorcyklopentadien; NCI-C55607; Perchloro-1,3-cyclopentadiene; Hccpd; PCL; Rcra waste number U130; 1,3-Cyclopentadiene, 1,2,3,4,5,5-hexachloro-; 1,2,3,4,5,5-Hexachloro-1,3-Cyclopentadiene; 1,2,3,4,5,5-Hexachloro-cyclopenta-1,3-diene; Hexachlorocyclopentadiène; Esaclorociclopentadiene


Application Chromatograms

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
GCxGC-TOFMS Contour Plot of Unfortified Detoxification Tea
GCxGC-TOFMS Contour Plot Showing Potential Isobaric Interference with Acephate (m/z 136) in 1D Analysis
GCxGC-TOFMS Contour Plot of Unfortified Berry Tea
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
Organochlorine Pesticides by U.S. EPA Method 8081A on Rtx-CLPesticides2 (dual column w/ Rtx-440)
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Low Bleed, High Efficiency MXT-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
Method 8081B Chlorinated Pesticides on Rtx-CLPesticides2
Organochlorine Pesticides by EPA Method 8081A on Rtx-440 (dual column w/ Rtx-CLPesticides2)
Semivolatiles on Rxi-5ms by EPA Method 525.2
Organochlorine Pesticides by EPA Method 8081B on Rtx-CLPesticides/Rtx-CLPesticides2 (extended list)
Organochlorine Pesticides by EPA 8081A on Rtx-CLPesticides & Rtx-CLPesticides2
Pesticides of U.S. EPA Method 505 on Rtx-CLPesticides and Rtx-CLPesticides2
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Pesticides & Herbicides U.S. EPA Method 508.1 Rtx-CLPesticides & Rtx-CLPesticides2
Semivolatiles CLP Method on Rtx-5MS
Chlorinated Disinfection Byproducts, Chlorinated Solvents, and Halogenated Pesticides by EPA 551.1 on Rtx-1301

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us