share:
delim
2-Methylbutane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Isopentane

CAS # 78-78-4


Compound Structure and Properties

Molecular Weight72.1488
FormulaC5H12
Melting Point-161--159 °C, 112-114 °K, -258--254 °F
Boiling Point28-28 °C, 300.9-301.3 °K, 82-83 °F
Density616 mg mL−1
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Butane, 2-methyl-; iso-Pentane; 1,1,2-Trimethylethane; 2-Methylbutane; iso-C5H12; Ethyldimethylmethane; Isoamylhydride; Exxsol isopentane; 1,1-dimethylpropane; methylbutane; Iso-Pentane * Isopentane; Exxsol isopentane S; NSC 119476


Application Chromatograms

PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Impurities in Commercial Cyclohexane on Rtx-DHA-100
Hydrocarbon Gases on Rt-Q-BOND
Refinery Gas on Rt-Q-BOND
Hydrocarbon Gases on Rt-Q-BOND
4-Hr Shipping Facility Air Sample with radiello 145
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Refinery Gas on Rtx-DHA-100 (ASTM D2163)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)
Isoparaffins on Rtx-DHA-100 (ASTM D6729-14)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Alkylate Standard on Rtx-DHA 50 by Method D5134-13
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-100 (ASTM D5441)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-150 (ASTM D5441)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-50 (ASTM D5441)
PAMS 57 Component Mix on Rtx-1 (105 m)
Reformate on Rtx-1
C1-C5 Hydrocarbons on Rt-Alumina BOND/MAPD
1,3-Butadiene on Rt-Alumina BOND/MAPD (Purity Analysis)
Crude 1,3-Butadiene on Rt-Alumina BOND/MAPD
Light Hydrocarbons on Rtx-DHA-150
Natural Gas (82% Methane) on Rtx-DHA-150
Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4
Mass APH on Rxi-1ms
Refinery Gas on Rt-Alumina BOND/KCl
Refinery Gas
Sim Dist by ASTM D3710 on Rtx-1 SimDist 2887 (calibration)
Sim Dist, ASTM D3710 (Gasoline) on Rtx-1 SimDist 2887
Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na2SO4
Refinery Gas Using OPN on Res-Sil C Packing
Refinery Gas Calibration Standard on Refinery Gas Packed Column Set
Sulfur Compounds and Hydrocarbons on Rt-XLSulfur
Refinery Gas on MXT-Alumina BOND/Na2SO4
Natural Gas #2 on Rt-QS-BOND
Ozone Precursors on Rtx-1
Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND/KCl, Rtx-1
Refinery Gas on Rt-Alumina BOND (Na2SO4)

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us