Trichloroethylene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Trichloroethylene

CAS # 79-01-6


Compound Structure and Properties

Molecular Weight131.3883
FormulaC2HCl3
Melting Point-73 °C, 200 °K, -99 °F
Boiling Point87.2 °C, 360 °K, 189 °F
Density1.46 g/cm3 (20 °C)
Solubility in Water1.280 g/L
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Trichloroethylene; Ethene, trichloro-; Ethylene, trichloro-; Algylen; Anamenth; Chlorilen; Chlorylen; Chorylen; Densinfluat; Ethinyl trichloride; Ethylene trichloride; Fluate; Gemalgene; Germalgene; Narcogen; Narkogen; Narkosoid; Threthylen; Threthylene; Trethylene; Tri; Tri-Clene; Trichloran; Trichloren; Trichloroethene


Application Chromatograms

TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Dynamic Headspace USP <467> solvents on Rtx-1301 (G43)
Volatile Organics (Canada) on Rtx-VMS
Volatile Organics TO-15 Volatiles on Rtx-1
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
EPA Method 524.2 on Rtx-502.2
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-5
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-200
Volatiles US EPA Method 624 on Rtx-624
USP <467> Residual Solvents on Rtx-1301 (G43) by Static Headspace
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents Class 2 Mixture B on Rtx-624
Halogenated Hydrocarbons on Rt-Alumina BOND/CFC
Residual Solvents (Class 2 - Mixture B) on Stabilwax (G16)
Residual Solvents Rxi-624Sil MS
Volatile Organics by EPA 8021 on Rtx-VRX
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Solvent Mixture on Rt-Q-BOND
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Chlorinated Disinfection Byproducts, Chlorinated Solvents, and Halogenated Pesticides by EPA 551.1 on Rtx-1301
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Residual Solvents (Class 2 - Mixture B) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix B Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us