share:
delim
Caryophyllene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Caryophyllene

CAS # 87-44-5


Compound Structure and Properties

Molecular Weight204.3511
FormulaC15H24
Boiling Point262-264 °F; 129-130 °C (14 mm Hg)
Density0.9052 g/cm3
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Caryophyllene; β-Caryophyllen; β-Caryophyllene; trans-Caryophyllene; L-Caryophyllene; Caryophyllene ,α + β mixt.; Beta-caryophyllene; 8-Methylene-4,11,11-(trimethyl)bicyclo(7.2.0)undec-4-ene; 4,11,11-Trimethyl-8-methylenebicyclo[7.2.0]undec-4-ene; (E)-Caryophyllene; (E)-β-Caryophyllene; trans-β-Caryophyllene; β-trans-caryophyllene; β-(E)-Caryophyllene; t-β-caryophyllene; β-Caryophillene; β-cariofillene; Caryophyllene (E); (E)-β-Caryophylene; Bicyclo[7.2.0]undec-4-ene, 4,11,11-trimethyl-8-methylene-, [1R-(1R*,4E,9S*)]-; Bicyclo[7.2.0]undec-4-ene, 4,11,11-trimethyl-8-methylene-, (E)-(1R,9S)-(-)-; Bicyclo(7.2.0)undec-4-ene, 8-methylene-4,11,11-trimethyl-, (E)-(1R,9S)-(-)-; 8-Methylene-4,11,11-(trimethyl)bicyclo(7.2.0)undec-4-ene, (1R,4E,9S)-; Caryophyllene, (E); E-β-Caryophyllene

Related Products


Application Chromatograms

Geranium Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Citronella Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Bergamot Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Lemon Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Peppermint Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Grapefruit Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Tea Tree Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Citronella Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Geranium Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Tea Tree Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Peppermint Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lavender Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Patchouli Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Rosemary Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Bergamot Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lemon Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Grapefruit Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lavender Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Rosemary Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Patchouli Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Lemongrass Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lemongrass Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Citronella Java Oil on Rtx-Wax
Patchouli Oil on Rtx-Wax
Lavender Oil on Rtx-Wax
Peppermint Oil on Rtx-Wax
Grapefruit Oil on Rtx-Wax
Tea Tree Oil on Rtx-Wax
Geranium Oil on Rtx-Wax
Lemongrass Oil on Rtx-Wax
Lemon Oil on Rtx-Wax
Bergamot Oil on Rxi-5Sil MS
Lemon Oil on Rxi-5Sil MS
Rosemary Oil on Rxi-5Sil MS
Patchouli Oil on Rxi-5Sil MS
Lavender Oil on Rxi-5Sil MS
Citronella Oil on Rxi-5Sil MS
Peppermint Oil on Rxi-5Sil MS
Grapefruit Oil on Rxi-5Sil MS
Tea Tree Oil on Rxi-5Sil MS
Geranium Oil on Rxi-5Sil MS
Lemongrass Oil on Rxi-5Sil MS
Rosemary Oil on Rtx-Wax
Cannabis Terpenes Standard #1 & #2 on Rxi-624Sil MS
Terpene Profile of Citra Hops on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Parsley on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Cascade Hops on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of UK East Kent Golding Hops on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Rosemary on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Thyme on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Sage on Rxi-624Sil MS by FET-HS-GC
Medical Cannabis Terpenes on Rxi-624Sil MS
Cannabis Terpenes on Rxi-624Sil MS by FET-HS-GC
Terpenes in Kryptonite Cannabis on Rxi-624Sil MS
Terpenes in Blueberry Jack Cannabis on Rxi-624Sil MS
Patchouli Oil Fast GC/MS on Rtx-5
Patchouli Oil Rtx-5Sil MS by GC/MS
Synthetic Essential Oil Mixture on Rtx-1
Flavor Volatiles on Rtx-1
Flavor Volatiles on Stabilwax
Lemon Oil on Rtx-5
Spearmint Oil (Native ) on Stabilwax
Peppermint Oil on MXT-WAX
Citronella Java Oil on Rtx-1
Citronella Java Oil Stabilwax

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us