α-Terpineol Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis
Find another compound:
Terpineol CAS # 98-55-5
Compound Structure and Properties Molecular Weight 154.2493 Formula C10 H18 O Melting Point 18 °C Boiling Point 219 °C 81-82 °C at 4.5 mmHg Density 0.9338 g/cm3
GC Mass Spectrum
m/zClick and drag to zoom, double click to reset zoom Hover over end of line for value.
Synonyms p-Menth-1-en-8-ol; α-Terpineol; Terpineol schlechthin; Terpineol; Terpineol, α; Terpenol; α-Terpinol; l-α-Terpineol; p-Menth-1-en-8-ol, (S)-(-)-; Lily of valley, artificial; 3-Cyclohexene-1-methanol, α,α4-trimethyl-; α,α,4-Trimethyl-3-Cyclohexene-1-methanol; alpha-Terpineol; 2-(4-methylcyclohex-3-enyl)propan-2-ol; Menth-1-en-8-ol; dl-α-Terpineol; 1-p-Menthen-8-ol; (.+/-.)-α-Terpineol; 2-(4-Methyl-3-cyclohexenyl)-2-propanol; 8-Hydroxy-p-menth-1-ene; NSC 21449; PC 593; Terpineol 350; 4-(2-Hydroxy-2-propyl)-1-methylcyclohexene; (+)-α-Terpineol
Geranium Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Citronella Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Bergamot Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Lemon Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Peppermint Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Tea Tree Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Citronella Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Geranium Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Tea Tree Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Peppermint Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lavender Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Rosemary Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Bergamot Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lemon Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Lavender Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Rosemary Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Citronella Java Oil on Rtx-Wax
Lavender Oil on Rtx-Wax
Grapefruit Oil on Rtx-Wax
Tea Tree Oil on Rtx-Wax
Geranium Oil on Rtx-Wax
Lemon Oil on Rtx-Wax
Bergamot Oil on Rxi-5Sil MS
Lemon Oil on Rxi-5Sil MS
Rosemary Oil on Rxi-5Sil MS
Lavender Oil on Rxi-5Sil MS
Citronella Oil on Rxi-5Sil MS
Peppermint Oil on Rxi-5Sil MS
Tea Tree Oil on Rxi-5Sil MS
Geranium Oil on Rxi-5Sil MS
Rosemary Oil on Rtx-Wax
Terpene Profile of Parsley on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Rosemary on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Thyme on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Sage on Rxi-624Sil MS by FET-HS-GC
Medical Cannabis Terpenes on Rxi-624Sil MS
Cannabis Terpenes on Rxi-624Sil MS by FET-HS-GC
Terpenes in Kryptonite Medical Cannabis on Rxi-624Sil MS
Terpenes in Blueberry Jack Medical Cannabis on Rxi-624Sil MS
Two Brands of Gin on Stabilwax-MS (Overlay)
Fragrance Allergens and Common Compounds in Commercial Perfume on Stabilwax-MS
Commercial Spearmint Oil on Stabilwax-MS
Flavor Compounds in Grappa on Stabilwax-DA
Synthetic Essential Oil Mixture on Rtx-1
Flavor Volatiles on Rtx-1
Flavor Volatiles on Stabilwax
Lemon Oil on Rtx-5
Spearmint Oil (Native ) on Stabilwax
Peppermint Oil on MXT-WAX
Mushroom Aroma (Synthetic) on Stabilwax
Citronella Java Oil on Rtx-1
Citronella Java Oil Stabilwax
Rosemary Oil on Rt-βDEXsm
Microbial VOCs on Rxi-1ms
Flavor & Fragrance Compounds Rt-CW20M F&F