Benzene, (1-methylethyl)- Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Cumene

CAS # 98-82-8


Compound Structure and Properties

Molecular Weight120.1916
FormulaC9H12
Melting Point-96 °C, 177 °K, -141 °F
Boiling Point152 °C, 425 °K, 306 °F
Density0.862 g cm−3, liquid
Solubility in Waterinsoluble
Data above sourced from ChemSpider and Wikipedia

GC Mass Spectrum

m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.

Synonyms

Benzene, (1-methylethyl)-; Cumene; Cumol; Isopropylbenzene; 2-Phenylpropane; (1-Methylethyl)benzene; Isopropylbenzol; Benzene, isopropyl-; Cumeen; Isopropilbenzene; Isopropylbenzeen; Isopropylbenzen; Propane, 2-phenyl-; 2-Fenilpropano; 2-Fenyl-propaan; Rcra waste number U055; (Methylethyl)benzene; iso-propylbenzene (cumene); benzene, i-propyl-; i-propylbenzene; (1-methylethyl)benzene (cumene); NSC 8776; UN 1918; Isopropylbenzène


Application Chromatograms

PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Cumene (Isopropylbenzene) on Rtx-1
Impurities in α-Methylstyrene on Rtx-1
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
Impurities in p-Xylene on Stabilwax
Styrene on Stabilwax
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Aromatics on Rtx-DHA-100 (ASTM D6729-14)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Residual Solvents Class 2 - Mix A (2013 Rev) on Stabilwax (G16)
Residual Solvents Class 2 — Mix A on Rxi-624Sil MS (G43) by USP <467>
PAMS 57 Component Mix on Rtx-1 (105 m)
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
Alcohols and Acetates on Stabilwax-MS
Solvent Mixture #1 on Rtx-1
Solvent Mixture #1 on Rtx-200
Solvent Mixture #1 on Stabilwax
Solvent Mixture #2 on Rtx-1
Solvent Mixture #2 on Rtx-200
Solvent Mixture #2 on Stabilwax
Solvent Mixture #3 on Rtx-1
Solvent Mixture #3 on Rtx-200
Volatile Organics US EPA Method 8260B on Rtx-VMS
Reformate on Rtx-1
Alaska Method AK101AA on Rtx-5Sil MS (PID)
Alaska Method AK101AA on Rtx-5Sil MS (FID)
Gasoline Aromatics on Rtx-1
Petroleum Oxygenates on Stabilwax
Gasoline Aromatics on Rtx-1
EPA Method 524.2, Revision 4 Rtx-VMS
Solvent Mixture #3 on Stabilwax
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
Styrene Impurities on Stabilwax
Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS, Overwrap at the Seam
EPA Method 524.2 on Rtx-502.2
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Styrene Impurities Rtx-1701
Aromatics on Rt-TCEP
Mass APH on Rxi-1ms
Aromatics, Aliphatics on 10% TCEP 100/120 Chromosorb® PAW
Aromatics (Xylene Isomers plus Cumene) on 5% RT-1200/1.75% Bentone 34 on 100/120 Silcoport
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8021 on Rtx-VRX
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us