p-Isopropyltoluene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis
Find another compound:
Cymene CAS # 99-87-6
Compound Structure and Properties Molecular Weight 134.2182 Formula C10 H14 Melting Point -68°C Boiling Point 177°C Density 0.857 g/cm3 Solubility in Water 23.4 mg/L
GC Mass Spectrum
m/zClick and drag to zoom, double click to reset zoom Hover over end of line for value.
Synonyms p-Cymene; p-Cimene; p-Cymol; p-Isopropyltoluene; p-Methylisopropylbenzene; Camphogen; Dolcymene; 1-Isopropyl-4-methylbenzene; 1-Methyl-4-isopropylbenzene; 2-p-Tolylpropane; 4-Isopropyl-1-methylbenzene; Cymol; Isopropyltoluene; Benzene, 1-isopropyl-4-methyl-; Cumene, p-methyl-; Cymene; p-Isopropylmethylbenzene; Paracymene; Paracymol; p-Methylcumene; 4-Isopropyltoluene; 4-Methylisopropylbenzene; Benzene, 1-methyl-4-(1-methylethyl)-; 1-Methyl-4-(1-methylethyl)-benzene; 1-(1-methylethyl)-4-methylbenzene
Bergamot Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Peppermint Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Tea Tree Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Tea Tree Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Peppermint Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Rosemary Oil on Rxi-5Sil MS (10 m, 0.15 mm ID, 0.15 µm)
Rosemary Oil on Rxi-5Sil MS (20 m, 0.18 mm ID, 0.18 µm)
Bergamot Oil on Rtx-Wax
Lavender Oil on Rtx-Wax
Grapefruit Oil on Rtx-Wax
Tea Tree Oil on Rtx-Wax
Lemon Oil on Rtx-Wax
Bergamot Oil on Rxi-5Sil MS
Lemon Oil on Rxi-5Sil MS
Rosemary Oil on Rxi-5Sil MS
Eucalyptus Oil on Rxi-5Sil MS
Peppermint Oil on Rxi-5Sil MS
Grapefruit Oil on Rxi-5Sil MS
Tea Tree Oil on Rxi-5Sil MS
Rosemary Oil on Rtx-Wax
Cumene (Isopropylbenzene) on Rtx-1
Impurities in α-Methylstyrene on Rtx-1
Cannabis Terpenes Standard #1 & #2 on Rxi-624Sil MS
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Aromatics on Rtx-DHA-100 (ASTM D6729-14)
Terpene Profile of Citra Hops on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Parsley on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Cascade Hops on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of UK East Kent Golding Hops on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Rosemary on Rxi-624Sil MS by FET-HS-GC
Terpene Profile of Thyme on Rxi-624Sil MS by FET-HS-GC
Cannabis Terpenes on Rxi-624Sil MS by FET-HS-GC
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
Commercial Spearmint Oil on Stabilwax-MS
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
Aromatics Stabilwax
Aromatics Rtx-502.2
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
EPA Method 524.2 on Rtx-502.2
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
Bergamot Oil Rtx-5Sil MS by GC/MS
Synthetic Essential Oil Mixture on Rtx-1
Flavor Volatiles on Rtx-1
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Flavor Volatiles on Stabilwax
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Lemon Oil on Rtx-5
Bergamot Oil Fast GC/MS on Rtx-5
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8021 on Rtx-VRX
Spearmint Oil (Native ) on Stabilwax
Peppermint Oil on MXT-WAX
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS